Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector
- 5 July 2005
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 24 (7) , 868-877
- https://doi.org/10.1109/tmi.2005.852501
Abstract
A compact, dedicated cadmium zinc telluride (CZT) gamma camera coupled with a fully three-dimensional (3-D) acquisition system may serve as a secondary diagnostic tool for volumetric molecular imaging of breast cancers, particularly in cases when mammographic findings are inconclusive. The developed emission mammotomography system comprises a medium field-of-view, quantized CZT detector and 3-D positioning gantry. The intrinsic energy resolution, sensitivity and spatial resolution of the detector are evaluated with Tc-99m (140 keV) filled flood sources, capillary line sources, and a 3-D frequency-resolution phantom. To mimic realistic human pendant, uncompressed breast imaging, two different phantom shapes of an average sized breast, and three different lesion diameters are imaged to evaluate the system for 3-D mammotomography. Acquisition orbits not possible with conventional emission, or transmission, systems are designed to optimize the viewable breast volume while improving sampling of the breast and anterior chest wall. Complications in camera positioning about the patient necessitate a compromise in these two orbit design criteria. Image quality is evaluated with signal-to-noise ratios and contrasts of the lesions, both with and without additional torso phantom background. Reconstructed results indicate that 3-D mammotomography, incorporating a compact CZT detector, is a promising, dedicated breast imaging technique for visualization of tumors <1 cm in diameter. Additionally, there are no outstanding trajectories that consistently yield optimized quantitative lesion imaging parameters. Qualitatively, imaging breasts with realistic torso backgrounds (out-of-field activity) substantially alters image characteristics and breast morphology unless orbits which improve sampling are utilized. In practice, the sampling requirement may be less strict than initially anticipated.Keywords
This publication has 42 references indexed in Scilit:
- Geometrical similarities of the Orlov and Tuy sampling criteria and a numerical algorithm for assessing sampling completenessIEEE Transactions on Nuclear Science, 2003
- Analysis of position-dependent Compton scatter in scintimammography with mild compressionIEEE Transactions on Nuclear Science, 2003
- Optimizing pinhole and parallel hole collimation for scintimammography with compact pixellated detectorsIEEE Transactions on Nuclear Science, 2003
- Implementation and initial characterization of acquisition orbits with a dedicated emission mammotomographIEEE Transactions on Nuclear Science, 2003
- Evaluation of breast tumor detectability with two dedicated, compact scintillation camerasIEEE Transactions on Nuclear Science, 2002
- SPECT breast imaging combining horizontal and vertical axes of rotationIEEE Transactions on Nuclear Science, 2002
- Breast tumor imaging using a tiltable head SPECT cameraIEEE Transactions on Nuclear Science, 2001
- Optimization of dedicated scintimammography procedure using detector prototypes and compressible phantomsIEEE Transactions on Nuclear Science, 2001
- CdZnTe solid-state gamma cameraIEEE Transactions on Nuclear Science, 1998
- Prone breast tumor imaging using vertical axis-of-rotation (VAOR) SPECT systems: an initial studyIEEE Transactions on Nuclear Science, 1997