Automatic detection of the electrocardiogram T-wave end
- 1 May 1999
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 37 (3) , 348-353
- https://doi.org/10.1007/bf02513311
Abstract
Various methods for automatic electrocardiogram T-wave detection and Q-T interval assessment have been developed. Most of them use threshold level corrsing. Comparisons with observer detection were performed due to the lack of objective measurement methods. This study followed the same approach. Observer assessments were performed on 43 various T-wave shapes recorded: (i) with 100 mms−1 equivalent paper speed and 0.5mVcm−1 sensitivity; and (ii) with 160 mms−1 paper speed and vertical scaling ranging from 0.07 to 0.02 m Vcm−1, depending on the T-wave amplitude. An automatic detection algorithm was developed by adequate selection of the T-end search interval, improved T-wave peak detection and computation of the angle between two 10ms long adjacent segments along the search interval. The algorithm avoids the use of baseline crossin direct signal differentiation. It performs well in cases of biphasic and/or complex T-wave shapes. Mean differences with respect to observer data are 13.5 ms for the higher gain/speed records and 14.7 ms for the lower gain/speed records. The algorithm was tested with 254 various T-wave shapes. Comparisons with two other algorithms are presented. The lack of a ‘gold standard’ for the T-end detection, especially if small waves occur around it, impeded adequate interobserver assessment and evaluation of automatic methods. It is speculated that a simultaneous presentation of normal and high-gain records might turn more attention to this problem. Automatic detection methods are in fact faced with ‘high-gain’ data, as high-resolution analogue-to-digital conversion, is already widely used.Keywords
This publication has 16 references indexed in Scilit:
- QT interval and dispersion in primary autonomic failure.Heart, 1996
- Diurnal pattern of QTc interval: How long is prolonged?: Possible relation to circadian triggers of cardiovascular eventsJournal of the American College of Cardiology, 1996
- Comparison of automatic QT measurement techniques in the normal 12 lead electrocardiogram.Heart, 1995
- Variation in the identification of Q wave initiation and its contribution to QT measurementPhysiological Measurement, 1995
- QT Dispersion: Problems of Methodology and Clinical SignificanceJournal of Cardiovascular Electrophysiology, 1994
- Time for yet another QT correction algorithm? Bazett and beyondJournal of the American College of Cardiology, 1994
- Errors in manual measurement of QT intervals.Heart, 1994
- QT dispersion and sudden unexpected death in chronic heart failureThe Lancet, 1994
- Importance of lead selection in QT interval measurementThe American Journal of Cardiology, 1988
- The Relationship between QT Interval and Ventricular Arrhythmias in Acute Myocardial InfarctionActa Medica Scandinavica, 1978