Comparison of replacement prostheses for segmental defects of bone. Different porous coatings for extracortical fixation.
- 1 February 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 70 (2) , 160-172
- https://doi.org/10.2106/00004623-198870020-00002
Abstract
The extent of extracortical bone-bridging and ingrowth into porous-coated prostheses for the stabilization of segmental defects was studied in a canine model. Initial fixation of the implant was achieved using bone cement. Autogenous bone grafts were applied over the porous-coated segmental portion of the prosthesis to stimulate the ingrowth and formation of bone. At twelve weeks, bone-bridging and ingrowth occurred uniformly in both the titanium fibermesh and the cobalt-chromium-molybdenum beaded prostheses. Maximum formation of osseous tissue over the implants occurred at two to four weeks. More bone formed in the posterior aspect of the prosthesis. At twelve weeks, 26 per cent of the porous space of the titanium fibermesh prosthesis and 47 per cent of the porous space of the cobalt-chromium-molybdenum beaded prosthesis were filled with bone. The torsional strength and stiffness of the prosthetic midsection that contained a conical coupling joint were increased significantly due to bone-bridging and ingrowth. The cortical bone that was apposed to the segmental prosthesis showed an increase in porosity. The use of bone cement did not appear to impede new-bone formation extracortically. The initial stability of the implant and the application of sufficient autogenous bone grafts are two important factors that contribute to the ultimate stable fixation of an implant by extracortical bone formation.Keywords
This publication has 13 references indexed in Scilit:
- Segmental Replacement of the Femur in Baboons with Fiber Metal Implants and Autologous Bone Grafts of Different Particle SizeActa Orthopaedica, 1982
- Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases.Journal of Bone and Joint Surgery, 1981
- A comparison of the effect of open intramedullary nailing and compression-plate fixation on fracture-site blood flow and fracture union.Journal of Bone and Joint Surgery, 1981
- Stress fields in the unplated and plated canine femur calculated from in vivo strain measurementsJournal of Biomechanics, 1981
- Autogenous cortical bone grafts in the reconstruction of segmental skeletal defects.Journal of Bone and Joint Surgery, 1980
- Prosthetic replacement of the knee and a large segment of the femur or tibia.Journal of Bone and Joint Surgery, 1979
- Microvascular anastomoses for bone grafts in the treatment of massive defects in bone.Journal of Bone and Joint Surgery, 1979
- Segmental replacement of long bones in baboons using a fiber titanium implant.Journal of Bone and Joint Surgery, 1978
- Resection-arthrodesis for malignant and potentially malignant lesions about the knee using an intramedullary rod and local bone graftsJournal of Bone and Joint Surgery, 1977
- Two-Color Fluorescent Labeling of Mineralizing Tissues with Tetracycline and 2,4-Bis[N,N'-Di-(Carbomethyl)Aminomethyl] FluoresceinStain Technology, 1966