On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers
- 25 July 2000
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (8) , 2331-2342
- https://doi.org/10.1088/0031-9155/45/8/318
Abstract
We have developed a densitometric method for measuring the isocentric accuracy and the accuracy of marking the isocentre position for linear accelerator based radiosurgery with circular collimators and room lasers. Isocentric shots are used to determine the accuracy of marking the isocentre position with room lasers and star shots are used to determine the wobble of the gantry and table rotation movement, the effect of gantry sag, the stereotactic collimator alignment, and the minimal distance between gantry and table rotation axes. Since the method is based on densitometric measurements, beam spot stability is implicitly tested. The method developed is also suitable for quality assurance and has proved to be useful in optimizing isocentric accuracy. The method is simple to perform and only requires a film box and film scanner for instrumentation. Thus, the method has the potential to become widely available and may therefore be useful in standardizing the description of linear accelerator based radiosurgical systems.Keywords
This publication has 9 references indexed in Scilit:
- Setup verification in linac‐based radiosurgeryMedical Physics, 1999
- Application of a video-optical beam imaging system for quality assurance of medical acceleratorsPhysics in Medicine & Biology, 1998
- Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS)Physics in Medicine & Biology, 1996
- The measurement of linear accelerator isocenter motion using a three-micrometer device and an adjustable pointerInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Precision and accuracy of stereotactic convergent beam irradiations from a linear acceleratorInternational Journal of Radiation Oncology*Biology*Physics, 1994
- Quality assurance in stereotactic radiosurgery using a standard linear acceleratorInternational Journal of Radiation Oncology*Biology*Physics, 1991
- A system for stereotactic radiosurgery with a linear acceleratorInternational Journal of Radiation Oncology*Biology*Physics, 1988
- Cerebral radiation surgery using moving field irradiation at a linear accelerator facilityInternational Journal of Radiation Oncology*Biology*Physics, 1985