High-resolution imaging reveals a limit in spatial resolution of blood flow measurements by microspheres
- 1 September 2004
- journal article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 287 (3) , H1132-H1140
- https://doi.org/10.1152/ajpheart.00119.2004
Abstract
Density of 15-μm microspheres after left atrial application is the standard measure of regional perfusion. In the heart, substantial differences in microsphere density are seen at spatial resolutions <5 ml, implying perfusion heterogeneity. Microsphere deposition imaging permits a superior evaluation of the distribution pattern. Therefore, fluorescent microspheres (FMS) were applied, FMS deposition in the canine heart was imaged by epifluorescence microscopy in vitro, and the patterns were observed compared with MR images of iron oxide microspheres (IMS) obtained in vivo and in vitro. FMS deposition in myocardial slices revealed the following: 1 ) a nonrandom distribution, with sequentially applied FMS of different color stacked within the same vessel, 2 ) general FMS clustering, and 3 ) rather large areas devoid of FMS ( n = 3). This pattern was also seen in reconstructed three-dimensional images (2 μM) enhanced local microsphere density, but did not alter the deposition pattern ( n = 3). The nonrandom, temporally stable pattern was quantitatively confirmed by a three-dimensional intermicrosphere distance analysis of sequentially applied FMS. T2-weighted short-axis MR images (2-μl resolution) of IMS revealed similar patterns in vivo and in vitro ( n = 6), as seen with FMS. The observed temporally stable microsphere patterns are not consistent with the notion that microsphere deposition is solely governed by blood flow. We propose that at high spatial resolution (<2 μl) structural aspects of the vascular network dominate microsphere distribution, resulting in the organized patterns observed.Keywords
This publication has 27 references indexed in Scilit:
- Combination of angiopoietin-1 and vascular endothelial growth factor gene therapy enhances arteriogenesis in the ischemic myocardiumBiochemical and Biophysical Research Communications, 2003
- Spatial heterogeneity in the heart: recent insights and open questions.Physiology, 2002
- Myocardial proteome analysis reveals reduced NOS inhibition and enhanced glycolytic capacity in areas of low local blood flowThe FASEB Journal, 2002
- Spatial heterogeneity of energy turnover in the heartPflügers Archiv - European Journal of Physiology, 2001
- Left Stellate Ganglion Block Has Only Small Effects on Left Ventricular Function in Awake Dogs Before and After Induction of Heart FailureAnesthesia & Analgesia, 2000
- Regional blood flow measurements from fluorescent microsphere images using an Imaging CryoMicrotomeReview of Scientific Instruments, 2000
- Autoradiographic Assessment of Blood Flow Heterogeneity in the Hamster HeartMicrocirculation, 1995
- Local Continuity of Myocardial Blood Flow Studied by Monochromatic Synchrotron Radiation–Excited X-ray Fluorescence SpectrometryCirculation Research, 1995
- Colored microspheres reveal interarterial microvascular anastomoses in canine myocardiumBasic Research in Cardiology, 1992
- The Circulation of the Fetus in UteroCirculation Research, 1967