Subsidence of an Uncemented Canine Femoral Stem
- 10 September 1992
- journal article
- Published by Wiley in Veterinary Surgery
- Vol. 21 (5) , 327-331
- https://doi.org/10.1111/j.1532-950x.1992.tb01705.x
Abstract
Factors contributing to subsidence were analyzed by radiographic evaluation and mechanical testing of 36 canine cadaver femora during and after insertion of an uncemented porous-coated femoral stem and by radiographic evaluation of 35 canine total hip arthroplasties. Mean percentage of canal fill in immediate postoperative radiographs, and percentage of canal fill at midimplant and distal implant locations, were accurate predictors of subsidence. Force required to implant the femoral stem was strongly correlated with force required for implant subsidence. Femoral morphology and percentage of canal fill at the middle and distal sites were accurate predictors of subsidence. Implants in femora with a stovepipe morphology (canal flare index less than or equal to 1.8) were six times more likely to subside than implants in femora that had a normal appearance (canal flare index 1.8 to 2.5), and 72 times more likely to subside than implants in champagne-fluted femora (canal flare index greater than or equal to 2.5). Femora with more than 85% mean, middle, or distal canal fill were less likely to subside.Keywords
This publication has 16 references indexed in Scilit:
- Implantation of an Uncemented Total Hip Prosthesis Technique and Initial Results of 100 ArthroplastiesVeterinary Surgery, 1992
- Radiographic Criteria for Evaluation of Uncemented Total Hip Replacement in DogsVeterinary Surgery, 1992
- Comparison of the stability of press‐fit hip prosthesis femoral stems using a synthetic model femurJournal of Orthopaedic Research, 1991
- Technical Aspects of Cementless Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1990
- Cemented Versus Cementless Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1990
- A Comparative Study of the Initial Stability of Cementless Hip ProsthesesClinical Orthopaedics and Related Research, 1989
- The Anatomic Basis of Femoral Component DesignClinical Orthopaedics and Related Research, 1988
- Strains and micromotions of press-fit femoral stem prosthesesJournal of Biomechanics, 1987
- Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced ImplantsClinical Orthopaedics and Related Research, 1986
- The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of BoneClinical Orthopaedics and Related Research, 1980