Balanced phase‐contrast steady‐state free precession (PC‐SSFP): A novel technique for velocity encoding by gradient inversion
- 15 April 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (5) , 945-952
- https://doi.org/10.1002/mrm.10451
Abstract
A technique for measuring velocity is presented that combines cine phase contrast (PC) MRI and balanced steady‐state free precession (SSFP) imaging, and is thus termed PC‐SSFP. Flow encoding was performed without the introduction of additional velocity encoding gradients in order to keep the repetition time (TR) as short as in typical SSFP imaging sequences. Sensitivity to through‐plane velocities was instead established by inverting (i.e., negating) all gradients along the slice‐select direction. Velocity sensitivity (VENC) could be adjusted by altering the first moments of the slice‐select gradients. Disturbances of the SSFP steady state were avoided by acquiring different flow echoes in consecutively (i.e., sequentially) executed scans, each over several cardiac cycles, using separate steady‐state preparation periods. A comparison of phantom measurements with those from established 2D‐cine‐PC MRI demonstrated excellent correlation between both modalities. In examinations of volunteers, PC‐SSFP exhibited a higher intrinsic signal‐to‐noise ratio (SNR) and consequently low phase noise in measured velocities compared to conventional PC scans. An additional benefit of PC‐SSFP is that it relies less on in‐flow‐dependent signal enhancement, and thus yields more uniform SNRs and better depictions of vessel geometry throughout the whole cardiac cycle in structures with slow and/or pulsatile flow. Magn Reson Med 49:945–952, 2003.Keywords
This publication has 19 references indexed in Scilit:
- Magnetization preparation during the steady state: Fat‐saturated 3D TrueFISPMagnetic Resonance in Medicine, 2001
- Fluctuating equilibrium MRIMagnetic Resonance in Medicine, 1999
- Motion‐insensitive, steady‐state free precession imagingMagnetic Resonance in Medicine, 1990
- Some factors that influence the steady state in steady-state free precessionMagnetic Resonance Imaging, 1988
- The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequencesMagnetic Resonance Imaging, 1988
- Spatial or flow velocity phase encoding gradients in NMR imagingMagnetic Resonance Imaging, 1984
- Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference TechniqueJournal of Computer Assisted Tomography, 1984
- Direct Cardiac NMR Imaging of Heart Wall and Blood Flow VelocityJournal of Computer Assisted Tomography, 1984
- A flow velocity zeugmatographic interlace for NMR imaging in humansMagnetic Resonance Imaging, 1982
- Steady-State Free Precession in Nuclear Magnetic ResonancePhysical Review B, 1958