Subtracted vortex centers path line method with cinematic angiography for measurement of flow speed in cerebral aneurysms
- 1 April 2008
- journal article
- Published by Taylor & Francis in Neurological Research
- Vol. 30 (3) , 251-255
- https://doi.org/10.1179/016164107x230658
Abstract
BACKGROUND AND PURPOSE: The assessment of blood flow speed by imaging modalities is of increasing importance for endovascular treatment, such as stent implantation, of cerebral aneurysms. The subtracted vortex centers path line method (SVC method) utilizes image post-processing for determining flow quantitatively. In current practice, intra-aneurysmal flow in an in vitro model is visualized by laser sheet translumination and digitally recorded. In this study, we applied this method to cinematic angiography (CA), which is the preferred imaging method for endovascular interventions, to analyse hemodynamic changes. The SVC method was applied to the images and compared with results of the slipstream line method with colored fluid. METHODS: A transparent tubular model was constructed of silicone which included an aneurysm 10 mm in diameter and having a 5 mm neck on a straight parent artery with a diameter of 3.5 mm. The model was integrated into a pulsatile circulation system. By CA, successive images at 25 frames/s with injection of contrast were obtained. RESULTS AND CONCLUSION: Rotating vortexes of contrast, which advanced along the wall of the aneurysm, were observed in successive images of the aneurysm cavity. This phenomenon was also observed in the successive images with the slipstream line method. The speed of the vortex center was calculated and the results show that the vortex speed of CA was the same as that under the slipstream line method. This indicates the possibility of applying the SVC method to medical imaging equipment for analysis of the flow in aneurysms containing stentKeywords
This publication has 18 references indexed in Scilit:
- Histological Postmortem Study of an Internal Carotid Artery Aneurysm Treated with the Neuroform StentNeurosurgery, 2005
- Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysmsJournal of Neurosurgery, 2005
- A lattice Boltzmann study of blood flow in stented aneurismFuture Generation Computer Systems, 2004
- The Neuroform Stent, the First Microcatheter-delivered Stent for Use in the Intracranial CirculationNeurosurgery, 2004
- Preliminary Experience Using the Neuroform Stent for the Treatment of Cerebral AneurysmsNeurosurgery, 2004
- Characterization of flow reduction properties in an aneurysm due to a stentPhysical Review E, 2003
- Changes of Flow Characteristics by Stenting in Aneurysm Models: Influence of Aneurysm Geometry and Stent PorosityAnnals of Biomedical Engineering, 2002
- Particle Image Velocimetry Assessment of Stent Design Influence on Intra-Aneurysmal FlowAnnals of Biomedical Engineering, 2002
- Computer Modeling of Intracranial Saccular and Lateral Aneurysms for the Study of Their HemodynamicsNeurosurgery, 1997
- Modeling of Flow in a Straight Stented and Nonstented Side Wall Aneurysm ModelJournal of Biomechanical Engineering, 1997