Flow in Prosthetic Heart Valves: State-of-the-Art and Future Directions
- 1 December 2005
- journal article
- review article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 33 (12) , 1689-1694
- https://doi.org/10.1007/s10439-005-8759-z
Abstract
Since the first successful implantation of a prosthetic heart valve four decades ago, over 50 different designs have been developed including both mechanical and bioprosthetic valves. Today, the most widely implanted design is the mechanical bileaflet, with over 170,000 implants worldwide each year. Several different mechanical valves are currently available and many of them have good bulk forward flow hemodynamics, with lower transvalvular pressure drops, larger effective orifice areas, and fewer regions of forward flow stasis than their earlier-generation counterparts such as the ball-and-cage and tilting-disc valves. However, mechanical valve implants suffer from complications resulting from thrombus deposition and patients implanted with these valves need to be under long-term anti-coagulant therapy. In general, blood thinners are not needed with bioprosthetic implants, but tissue valves suffer from structural failure with, an average life-time of 10–12 years, before replacement is needed. Flow-induced stresses on the formed elements in blood have been implicated in thrombus initiation within the mechanical valve prostheses. Regions of stress concentration on the leaflets during the complex motion of the leaflets have been implicated with structural failure of the leaflets with bioprosthetic valves. In vivo and in vitro experimental studies have yielded valuable information on the relationship between hemodynamic stresses and the problems associated with the implants. More recently, Computational Fluid Dynamics (CFD) has emerged as a promising tool, which, alongside experimentation, can yield insights of unprecedented detail into the hemodynamics of prosthetic heart valves. For CFD to realize its full potential, however, it must rely on numerical techniques that can handle the enormous geometrical complexities of prosthetic devices with spatial and temporal resolution sufficiently high to accurately capture all hemodynamically relevant scales of motion. Such algorithms do not exist today and their development should be a major research priority. For CFD to further gain the confidence of valve designers and medical practitioners it must also undergo comprehensive validation with experimental data. Such validation requires the use of high-resolution flow measuring tools and techniques and the integration of experimental studies with CFD modeling.Keywords
This publication has 22 references indexed in Scilit:
- Research approaches for studying flow-induced thromboembolic complications in blood recirculating devicesExpert Review of Medical Devices, 2004
- Three-component laser doppler velocimetry measurements in the regurgitant flow region of a björk-shiley monostrut mitral valveAnnals of Biomedical Engineering, 1997
- A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: Comparison of experimental and numerical resultsJournal of Biomechanics, 1996
- Frequency and severity of intravascular hemolysis after left-sided cardiac valve replacement with medtronic hall and St. Jude medical prostheses, and influence of prosthetic type, position, size and numberThe American Journal of Cardiology, 1993
- Blood rheology after cardiac valve replacement with mechanical prostheses or bioprosthesesThe American Journal of Cardiology, 1991
- 1 - ApheresisThe International Journal of Artificial Organs, 1990
- Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stressesBiorheology, 1984
- Laser anemometry measurements of pulsatile flow past aortic valve prosthesesJournal of Biomechanics, 1983
- Intravascular hemolysis in the late course of aortic valve replacement. Relation to valve type, size, and functionAmerican Heart Journal, 1978
- Studies of Platelet and Fibrinogen Kinetics in Patients with Prosthetic Heart ValvesNew England Journal of Medicine, 1970