Assessment of hypoglycaemia awareness using continuous glucose monitoring
- 20 February 2004
- journal article
- research article
- Published by Wiley in Diabetic Medicine
- Vol. 21 (5) , 487-490
- https://doi.org/10.1111/j.1464-5491.2004.1136.x
Abstract
Aims To investigate the possibility of assessing hypoglycaemia awareness in patients with Type 1 diabetes using continuous glucose monitoring.Methods Twenty patients with Type 1 diabetes were investigated. Ten patients with Type 1 diabetes and strongly impaired hypoglycaemia awareness were compared with 10 patients with intact hypoglycaemia awareness regarding quality of hypoglycaemia perception (number of undetected hypoglycaemic episodes per 24 h, glucose level < 3.3 mmol/l). Hypoglycaemia detection was assessed using the event function of the Continuous Glucose Monitoring System (CGMS™; Medtronic MiniMed®, Northridge, CA, USA). Patients were instructed to enter an event upon suspecting being hypoglycaemic.Results Satisfactory CGMS performance could be achieved [mean r = 0.893 between calibration measurements and CGMS data, mean absolute difference (MAD) = 20.6%], although artefacts were observable and had to be controlled. Hypoglycaemia unaware patients showed a significantly higher total number of hypoglycaemic episodes (P < 0.05), number of undetected hypoglycaemic episodes (P < 0.01), and mean glucose levels (P < 0.05). Even in aware patients, undetected hypoglycaemia was observable. No significant differences regarding occurrence of nocturnal hypoglycaemia were observable.Conclusions The possibility of direct assessment of hypoglycaemia awareness using continuous glucose monitoring was demonstrated. Its application in clinical practice could be of use for assessing hypoglycaemia perception and evaluating the impact of treatment changes on hypoglycaemia awareness.Keywords
This publication has 13 references indexed in Scilit:
- Spurious Reporting of Nocturnal Hypoglycemia by CGMS in Patients With Tightly Controlled Type 1 DiabetesDiabetes Care, 2002
- A Pilot Study of the Continuous Glucose Monitoring SystemDiabetes Care, 2001
- Limitations of Conventional Methods of Self-Monitoring of Blood GlucoseDiabetes Care, 2001
- Efficacy and Reliability of the Continuous Glucose Monitoring SystemDiabetes Technology & Therapeutics, 2000
- Hypoglycemia and the Hypoglycemic Unawareness SyndromeDiabetes Technology & Therapeutics, 2000
- Symptom reporting in asthma patients and insulin-dependent diabeticsBiological Psychology, 1996
- Reduced Awareness of Hypoglycemia in Adults With IDDM: A prospective study of hypoglycemic frequency and associated symptomsDiabetes Care, 1995
- Frequency of Severe Hypoglycemia in Patients With Type I Diabetes With Impaired Awareness of HypoglycemiaDiabetes Care, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993