OBJECTIVE—To determine whether the continuous glucose monitoring system (CGMS) (MiniMed, Sylmar, CA) could be used to make clinical decisions and whether it has an impact on glycemia in pediatric type 1 diabetic subjects. RESEARCH DESIGN AND METHODS—Pediatric subjects were recruited if they had HbA1c >8.0% with management problems (n = 35) or episodes of severe or nocturnal hypoglycemia or hypoglycemia unawareness associated with HbA1c ≤8.0% (n = 12). A total of 47 patients with a mean HbA1c value of 8.6 ± 1.6% (mean age 11.8 ± 4.6 years, youngest 2.7 years, and diabetes duration 5.5 ± 3.5 years) on three to four insulin injections/day (n = 24) or insulin pump therapy (n = 23) were followed with the CGMS for a mean of 69.5 ± 28 h. Comparisons were made between the number of high (>150 mg/dl) and low (1c levels were evaluated. RESULTS—In patients on injection therapy, 30 high or low glucose patterns were discerned with the logbook records and 120 patterns with the CGMS. Specific alterations of the diabetes regimen were made. An overall significant change in HbA1c, from 3 months before wearing the sensor to 6 months after (analysis of variance 0.04), was found in the subjects. Post hoc analysis showed a significant change in HbA1c from 8.6 ± 1.5% at baseline to 8.4 ± 1.3% at 3 months (paired Student’s t test 0.03). CONCLUSIONS—The CGMS can be used by pediatric patients to detect abnormal patterns of glycemia. The information that was obtained could be used to alter the diabetes regimen and impact glycemic outcome.Keywords
This publication has 13 references indexed in Scilit:
- Continuous Subcutaneous Glucose Monitoring in Children With Type 1 DiabetesPediatrics, 2001
- Therapy focused on lowering postprandial glucose, not fasting glucose, may be superior for lowering HbA1c. IOEZ Study Group.Diabetes Care, 2000
- Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home UseDiabetes Technology & Therapeutics, 2000
- Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot studyDiabetes Research and Clinical Practice, 1999
- Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoringAmerican Journal of Physiology-Endocrinology and Metabolism, 1999
- Use of a plastic insulin dosage guide to correct blood glucose levels out of the target range and for carbohydrate counting in subjects with type 1 diabetes.Diabetes Care, 1999
- Factors Associated With Glycemic Control: A cross-sectional nationwide study in 2,579 French children with type 1 diabetesDiabetes Care, 1998
- Nocturnal hypoglycemia in children and adolescents with insulin-dependent diabetes mellitus: Prevalence and risk factorsThe Journal of Pediatrics, 1997
- Incidence and predictive criteria of nocturnal hypoglycemia in young children with insulin-dependent diabetes mellitusThe Journal of Pediatrics, 1997
- Hypoglycemia Unawareness in IDDMDiabetes Care, 1993