Precision and Accuracy Considerations of Physiological Quantitation in PET
Open Access
- 1 March 1991
- journal article
- review article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 11 (1_suppl) , A45-A50
- https://doi.org/10.1038/jcbfm.1991.36
Abstract
The ability to differentiate regional patterns of flow and metabolism between various patient populations depends upon the signal-to-noise characteristics of the data. The approach chosen for producing quantitative data will affect the detection sensitivity of a method. Methods based on mathematical models can reduce intersubject variability by accounting for factors unrelated to the physiological measure of interest, in particular, differences in the input function. However, errors in the model and in the implementation of a model-based method can increase variability compared to simpler, empirical methods. Normalization of physiological measures can significantly reduce intersubject variation; however, interpretation of normalized results can be more complex. The advantages and disadvantages of various approaches for physiological quantitation are considered.Keywords
This publication has 26 references indexed in Scilit:
- Simultaneous Determination of Regional Cerebral Blood Flow, Glucose Metabolism, and pH in Acute Experimental Allergic EncephalomyelitisJournal of Cerebral Blood Flow & Metabolism, 1987
- Effect of Vascular Activity in the Determination of Rate Constants for the Uptake of 18F-Labeled 2-Fluoro-2-Deoxy-D-Glucose: Error Analysis and Normal Values in Older SubjectsJournal of Cerebral Blood Flow & Metabolism, 1986
- Weighted Integration Method for Local Cerebral Blood Flow Measurements with Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1986
- Strategy for the Measurement of Regional Cerebral Blood Flow Using Short-Lived Tracers and Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1984
- Alternative Approach to Single-Scan Estimation of Cerebral Glucose Metabolic Rate Using Glucose Analogs, with Particular Application to IschemiaJournal of Cerebral Blood Flow & Metabolism, 1984
- Effect of Tissue Heterogeneity on the Measurement of Cerebral Blood Flow with the Equilibrium C15O2 Inhalation TechniqueJournal of Cerebral Blood Flow & Metabolism, 1983
- Use of 2-Deoxy-D[1-11C]Glucose for the Determination of Local Cerebral Glucose Metabolism in Humans: Variation within and between SubjectsJournal of Cerebral Blood Flow & Metabolism, 1982
- A Statistical Study of the Steady State Technique for Measuring Regional Cerebral Blood Flow and Oxygen Utilisation Using 15OJournal of Computer Assisted Tomography, 1982
- Measurement of Local Blood Flow and Distribution Volume with Short-Lived Isotopes: A General Input TechniqueJournal of Cerebral Blood Flow & Metabolism, 1982
- A theoretical study of quantitative flow measurements with constant infusion of short-lived isotopesPhysics in Medicine & Biology, 1979