Protection of Occupants from Exhaled Infectious Agents and Floor Material Emissions in Rooms with Personalized and Underfloor Ventilation
- 1 January 2007
- journal article
- research article
- Published by Taylor & Francis in HVAC&R Research
- Vol. 13 (1) , 23-38
- https://doi.org/10.1080/10789669.2007.10390942
Abstract
The performance of two personalized ventilation systems supplying air at the breathing zone was tested in conjunction with underfloor ventilation generating two different airflow patterns in a full-scale test room. Two breathing thermal manikins were used to simulate occupants. The distribution of pollutants associated with exhaled air and floor material emissions was evaluated at various combinations of personalized and underfloor airflow rates. Compared to underfloor ventilation alone, personalized and underfloor ventilation provided excellent protection of seated occupants from any pollution, while the concentration of exhaled air pollution increased in the room. The two types of personalized ventilation performed differently. Subsequent analyses of airborne infection transmission risk indicated that personalized ventilation could become a supplement to traditional methods of infection control.Keywords
This publication has 15 references indexed in Scilit:
- Performance of Personalized Ventilation in Conjunction with Mixing and Displacement VentilationHVAC&R Research, 2006
- Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong KongIndoor Air, 2004
- Ventilation efficiencies and thermal comfort results of a desk-edge-mounted task ventilation systemIndoor Air, 2004
- Human response to personalized ventilation and mixing ventilationIndoor Air, 2004
- Multi-zone modeling of probable SARS virus transmission by airflow between flats in Block E, Amoy GardensIndoor Air, 2004
- The Association between Asthma and Allergic Symptoms in Children and Phthalates in House Dust: A Nested Case–Control StudyEnvironmental Health Perspectives, 2004
- Personalized ventilationIndoor Air, 2004
- Interior surface materials in the home and the development of bronchial obstruction in young children in Oslo, Norway.American Journal of Public Health, 1999
- Application of the Field and Laboratory Emission Cell "FLEC" - Performance Study, Intercomparison Study, and Case Study of Damaged Linoleum in an Office#Indoor Air, 1995
- Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic LiteratureIndoor Air, 1993