Problems in determining levels of free digoxin in patients treated with digoxin immune fab
- 1 January 1995
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 9 (6) , 407-412
- https://doi.org/10.1002/jcla.1860090612
Abstract
Determination of free digoxin levels in patients treated with digoxin immune FAb has long been a problematic area in clinical laboratory testing. The older radioimmunoassays resulted in inaccurate and variable results due to the competition of the administered drug with the radioactively labelled forms. The 1995 Physicians' Desk Reference continues to state that digoxin immune FAb will interfere with digitalis immunoassay measurements. This statement, however, is based primarily on the RIA methods. We evaluated the Stratus digoxin assay and the TDX digoxin II assay. Increasing amounts of immune FAb were added in a stepwise fashion to 12 patient samples containing high normal to elevated digoxin levels. Results showed a progressive decrease in digoxin levels when assayed with the Stratus kit. However, five patient samples tested with the TDX kit resulted in constant digoxin values despite the presence of increasing digibind levels. These results suggest that the Stratus method measures free digoxin, whereas the TDX method measures the total digoxin. Measurement of digoxin by the Stratus method is simple and quick. The Stratus digoxin assay may be an accurate and objective way of measuring free digoxin levels in patients on digoxin immune FAb.Keywords
This publication has 12 references indexed in Scilit:
- Incidence of hospitalization for digitalis toxicity among elderly AmericansThe American Journal of Medicine, 1994
- Determination of Free Serum Digoxin Concentrations in Digoxin Toxic Patients After Administration of Digoxin Fab AntibodiesTherapeutic Drug Monitoring, 1992
- Treatment of 150 cases of life-threatening digitalis intoxication with digoxin-specific Fab antibody fragments. Final report of a multicenter study.Circulation, 1990
- Effect of Digoxin Fab Antibodies on Five Digoxin ImmunoassaysTherapeutic Drug Monitoring, 1990
- Effects of Digoxin Immune Fab (ovine) on Digoxin ImmunoassaysAmerican Journal of Clinical Pathology, 1989
- Determination of free digoxin concentrations in serum for monitoring Fab treatment of digoxin overdose.Clinical Chemistry, 1987
- Digoxin--issues and controversies.Clinical Chemistry, 1986
- Treatment of 63 severely digitalis-toxic patients with digoxin-specific antibody fragmentsJournal of the American College of Cardiology, 1985
- Plasma digoxin: assay anomalies in Fab-treated patients.Published by Wiley ,1983
- Reversal of Advanced Digoxin Intoxication with Fab Fragments of Digoxin-Specific AntibodiesNew England Journal of Medicine, 1976