Stability of the input-output properties of chronically implanted multiple contact nerve cuff stimulating electrodes
- 1 December 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Rehabilitation Engineering
- Vol. 6 (4) , 364-373
- https://doi.org/10.1109/86.736150
Abstract
The objective of this investigation was to measure the input-output (EO) properties of chronically implanted nerve cuff electrodes. Silicone rubber spiral nerve cuff electrodes, containing 12 individual platinum electrode contacts, were implanted on the sciatic nerve of 7 adult cats for 28-34 weeks. Measurements of the torque generated at the ankle joint by electrical stimulation of the sciatic nerve were made every 1-2 weeks for the first 6 weeks post-implant and every 3-5 weeks between 6 weeks and 32 weeks post-implant. In 3 implants the percutaneous lead cable was irreparably damaged by the animal within 4 weeks after implant and further testing was not possible. One additional lead cable was irreparably damaged by the animal at 17 weeks post-implant. The 3 remaining implants functioned for 28, 31, and 32 weeks. Input-output curves of ankle joint torque as a function of stimulus current amplitude were repeatable within an experimental session, but there were changes in EO curves between sessions. The degree of variability in I-O properties differed between implants and between different contacts within the same implant. After 8 weeks, the session to session changes in the stimulus amplitude required to generate 50% of the maximum torque (150) were smaller (15/spl plusmn/19%, mean /spl plusmn/s.d.) than the changes in 150 measured between 1 week and 8 weeks post-implant (34/spl plusmn/42%). Furthermore, the I-O properties were more stable across changes in limb position in the late post-implant period than in acutely implanted cuff electrodes. These results suggest that tissue encapsulation acted to stabilize chronically implanted cuff electrodes. Electrode movement relative to the nerve, de- and regeneration of nerve fibers, and the inability to precisely reproduce limb position in the measurement apparatus all may have contributed to the variability in I-O properties.Keywords
This publication has 25 references indexed in Scilit:
- Recruitment characteristics of nerve fascicles stimulated by a multigroove electrodeIEEE Transactions on Rehabilitation Engineering, 1997
- Quantification of recruitment properties of multiple contact cuff electrodesIEEE Transactions on Rehabilitation Engineering, 1996
- Perspectives on new electrode technology for stimulating peripheral nerves with implantable motor prosthesesIEEE Transactions on Rehabilitation Engineering, 1995
- Selective control of muscle activation with a multipolar nerve cuff electrodeIEEE Transactions on Biomedical Engineering, 1993
- Neural prosthetic interfaces with the nervous systemTrends in Neurosciences, 1989
- A modeling study of nerve fascicle stimulationIEEE Transactions on Biomedical Engineering, 1989
- Technology and Long-term Application of an Epineural ElectrodeAnnual Northeast Bioengineering Conference, 1989
- A spiral nerve cuff electrode for peripheral nerve stimulationIEEE Transactions on Biomedical Engineering, 1988
- A Primate Model for Chronic Nerve CompressionJournal of Reconstructive Microsurgery, 1985
- Experience with implanted electrodesNeurosurgery, 1977