Perfusion‐based high‐resolution functional imaging in the human brain at 7 Tesla
Open Access
- 22 April 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (5) , 903-911
- https://doi.org/10.1002/mrm.10154
Abstract
Perfusion‐based MRI measures cerebral blood flow (CBF) at the capillary level and can be used for functional studies based on the tight spatial coupling between brain activity and blood flow. Obtaining functional CBF maps with high spatial resolution is a major challenge because the CBF signal is intrinsically low and the SNR is critical. In the present work, CBF‐based functional imaging was performed at a considerably smaller voxel size than previously reported in humans. High‐resolution CBF maps were obtained with voxel sizes as small as 0.9 × 0.9 × 1.5 mm3 in the human brain. High sensitivity was made possible by signal‐to‐noise gains at the high magnetic field of 7 T and by using a novel RF combination coil design. In addition, a reduction of the field‐of‐view was critical to achieve 0.9‐mm in‐plane resolution with gradient‐echo echo‐planar imaging in a single shot. Functional CBF data were compared with functional BOLD data to reveal that, for CBF, large contrast‐ to‐noise gains were obtained at high spatial resolution, indicating that the functional CBF response was more localized. High‐resolution functional CBF imaging is significant for neuroscience research because it provides better localization and more specific information than BOLD for monitoring brain function. Magn Reson Med 47:903–911, 2002.Keywords
This publication has 26 references indexed in Scilit:
- High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxelsMagnetic Resonance in Medicine, 2001
- Comparison of simultaneously measured perfusion and BOLD signal increases during brain activation withT1-based tissue identificationMagnetic Resonance in Medicine, 2000
- Determination of relative CMRO2 from CBF and BOLD changes: Significant increase of oxygen consumption rate during visual stimulationMagnetic Resonance in Medicine, 1999
- Cerebral Blood Flow Measurements by Magnetic Resonance Imaging Bolus Tracking: Comparison with [15O]H2O Positron Emission Tomography in HumansJournal of Cerebral Blood Flow & Metabolism, 1998
- Stimulate: A GUI based fMRI analysis software packageNeuroImage, 1996
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- Image reconstruction for echo planar imaging with nonequidistant k‐space samplingMagnetic Resonance in Medicine, 1992
- Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effectsMagnetic Resonance in Medicine, 1988
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986
- Highly selective π2 and π pulse generationJournal of Magnetic Resonance (1969), 1984