Abstract
The aim of this study was to determine the incidence and frequency of cerebral embolic signals in a patient population with the same mechanical heart valve using transcranial Doppler examination. Furthermore, it aimed to identify patient and valve characteristics that correlated with the occurrence of these signals. Ninety-two patients with Carbomedics valves and 15 healthy control subjects took part in the study. Thirty-six patients were examined before and immediately after valve implantation (group 1), 34 patients 1 year after surgery (group 2), and 22 patients 5 years after surgery (group 3). Cerebral embolic signals were detected using transcranial Doppler monitoring of the right middle cerebral artery. Asymptomatic cerebral embolic signals were detected in 87% of the total 92 patients, in 77.8% of group 1 patients, in 91.2% of group 2 patients, and in 95.5% of group 3 patients. No cerebral embolic signals were detected in group 1 patients before surgery or in control subjects. The incidence (P = .04) and frequency (P = .002) of cerebral embolic signals increased significantly with longer duration of valve implantation. A significant positive correlation was also found between frequency of cerebral embolic signals and valve size (r = .4326, P = .00001). Median frequency of embolic signals in patients with a history suggestive of cerebrovascular events (n = 14) was 60 signals per hour compared with 11 signals per hour in those with no such history (n = 42; P = .04). The incidence and frequency of cerebral embolic signals increased with the duration of valve implantation. The frequency of these signals also was dependent on valve size. Patients who had experienced cerebrovascular symptoms had a higher frequency of cerebral embolic signals compared with those with no such signals. These results should be interpreted with caution but suggest that this method could be of help in assessing the risk of stroke in prosthetic heart valve patients and that prospective clinical studies should now be carried out.Keywords
This publication has 14 references indexed in Scilit:
- Subclinical embolism in patients undergoing cardiac valve implantation and coronary artery bypass surgeryEuropean Journal of Cardio-Thoracic Surgery, 1994
- A Comparison of Aspirin with Placebo in Patients Treated with Warfarin after Heart-Valve ReplacementNew England Journal of Medicine, 1993
- Hemodynamic evaluation of the Carbomedics prosthetic heart valve in the aortic position: Comparison of noninvasive and invasive techniquesAmerican Heart Journal, 1992
- Mechanical cardiac valvular prosthesesThe Annals of Thoracic Surgery, 1991
- Blood rheology after cardiac valve replacement with mechanical prostheses or bioprosthesesThe American Journal of Cardiology, 1991
- Trial of Different Intensities of Anticoagulation in Patients with Prosthetic Heart ValvesNew England Journal of Medicine, 1990
- Left atrial dimension and risk of systemic embolism in patients with a prosthetic valveJournal of the American College of Cardiology, 1990
- RATES OF THROMBOEMBOLISM WITH THREE DIFFERENT MECHANICAL HEART VALVE PROSTHESES: RANDOMISED STUDYThe Lancet, 1989
- Morbidity in Valvular Heart Replacement: Risk Factors of Systemic Emboli and Thrombotic ObstructionThe International Journal of Artificial Organs, 1988
- Thrombotic and Bleeding Complications of Prosthetic Heart ValvesThe Annals of Thoracic Surgery, 1987