Propeller EPI in the other direction
- 4 May 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (6) , 1298-1307
- https://doi.org/10.1002/mrm.20890
Abstract
A new propeller EPI pulse sequence with reduced sensitivity to field inhomogeneities is proposed. Image artifacts such as blurring due to Nyquist ghosting and susceptibility gradients are investigated and compared with those obtained in previous propeller EPI studies. The proposed propeller EPI sequence uses a readout that is played out along the short axis of the propeller blade, orthogonal to the readout used in previous propeller methods. In contrast to long‐axis readout propeller EPI, this causes the echo spacing between two consecutive phase‐encoding (PE) lines to decrease, which in turn increases the k‐space velocity in this direction and hence the pseudo‐bandwidth. Long‐ and short‐axis propeller EPI, and standard single‐shot EPI sequences were compared on phantoms and a healthy volunteer. Diffusion‐weighted imaging (DWI) was also performed on the volunteer. Short‐axis propeller EPI produced considerably fewer image artifacts compared to the other two sequences. Further, the oblique blades for the long‐axis propeller EPI were also prone to one order of magnitude higher residual ghosting than the proposed short‐axis propeller EPI. Magn Reson Med, 2006.Keywords
This publication has 13 references indexed in Scilit:
- PROPELLER EPI: An MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortionsMagnetic Resonance in Medicine, 2005
- Removal of EPI Nyquist ghost artifacts with two‐dimensional phase correctionMagnetic Resonance in Medicine, 2004
- How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imagingNeuroImage, 2003
- Centering the projection reconstruction trajectory: Reducing gradient delay errorsMagnetic Resonance in Medicine, 2003
- Distortion correction and robust tensor estimation for MR diffusion imagingMedical Image Analysis, 2002
- A Model-Based Method for Retrospective Correction of Geometric Distortions in Diffusion-Weighted EPINeuroImage, 2002
- Elimination of Nyquist ghosting caused by read‐out to phase‐encode gradient cross‐terms in EPIMagnetic Resonance in Medicine, 2002
- Resampling of data between arbitrary grids using convolution interpolationIEEE Transactions on Medical Imaging, 1999
- Image reconstruction for echo planar imaging with nonequidistant k‐space samplingMagnetic Resonance in Medicine, 1992
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991