Fundamentals of Capillary Electrochromatography: Migration Behavior of Ionized Sample Components
- 15 January 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (4) , 762-770
- https://doi.org/10.1021/ac010968t
Abstract
The mechanism of separating charged species by capillary electrochromatography (CEC) was modeled with the conditions of ideal/linear chromatography by using a simple random walk. The most novel aspect of the work rests with the assumption that in sufficiently high electric field ionized sample components can also migrate in the adsorbed state on the ionized surface of the stationary phase. This feature of CEC leads to the introduction of three dimensionless parameters: α, reduced mobility of a sample component with the electrosmotic mobility as the reference; β, the CEC retention factor; and γ, the ratio of the electrophoretic migration velocity and the velocity of surface electrodiffusion. Since the interplay of retentive and electrophoretic forces determines the overall migration velocity, the separation mechanism in CEC is governed by the relative importance of the above parameters. The model predicts conditions under which the features of the CEC system engender migration behavior that manifests itself in a relatively narrow elution window and in a gradient like elution pattern in the separation of peptides and proteins by using pro forma isocratic CEC. It is believed that such elution patterns, which resemble those obtained by the use of external gradient of the eluent, are brought about by the formation of an internal gradient in the CEC system that gave rise to concomitant peak compression. The peculiarities of CEC are discussed in the three operational modalities of the technique: co-current, countercurrent, and co-counter CEC. The results suggest that CEC, which is often called “liquid chromatography on electrophoretic platform” is an analytical tool with great potential in the separation of peptides and proteins.Keywords
This publication has 17 references indexed in Scilit:
- Reversed-phase electrochromatography of amino acids and peptides using porous polymer monolithsJournal of Chromatography A, 2001
- Rapid separation of peptides and proteins by isocratic capillary electrochromatography at elevated temperatureJournal of Chromatography A, 2001
- Comparison of Empirical Peak Capacities for High-Efficiency Capillary Chromatographic TechniquesAnalytical Chemistry, 2001
- Separation of sulfonamides by capillary electrochromatographyChromatographia, 2001
- Separation of basic solutes by reversed-phase capillary electrochromatographyJournal of Chromatography A, 2000
- Separation of pharmaceutical bases from neutral and acidic components by capillary electrochromatographyAnalytical Communications, 1998
- Capillary electrochromatography — a high-efficiency micro-separation techniqueJournal of Chromatography A, 1996
- Separation parameters via virtual migration distances in high-performance liquid chromatography, capillary zone electrophoresis and electrokinetic chromatographyJournal of Chromatography A, 1996
- Pressurized gradient electro-high-performance liquid chromatographyJournal of Chromatography A, 1994
- Chromatographic behavior in electrochromatographyAnalytical Chemistry, 1988