Load dependence of left ventricular diastolic pressure-volume relations during short-term coronary artery occlusion.
- 1 February 1991
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 83 (2) , 661-673
- https://doi.org/10.1161/01.cir.83.2.661
Abstract
We evaluated the effect of altered loading conditions on left ventricular (LV) diastolic pressure-volume relations during acute coronary artery occlusion that was produced by inflation of an intracoronary balloon. Open-chest anesthetized dogs (n = 18) were instrumented so that LV pressure (micromanometer) and LV volume (conductance) could be measured without disturbing the pericardium. The effects of brief periods of occlusion (1-2 minutes) were assessed under steady-state conditions before and after dextran infusion with the pericardium present and absent and during vena caval occlusion. Under steady-state conditions before dextran infusion with the pericardium removed, at an LV end-diastolic pressure (EDP) of 8.4 +/- 1.4 mm Hg, occlusion resulted in a rightward shift in the diastolic portion of the LV pressure-volume loop (delta LVEDP, 2.7 +/- 2.3 mm Hg; delta LVEDV, 6.3 +/- 4.7 ml, both p less than 0.05 versus control). After dextran infusion (LVEDP, 20.9 +/- 6.0 mm Hg), occlusion resulted in a rightward and upward shift in the diastolic portion of the LV pressure-volume loop (delta LVEDP, 5.8 +/- 4.4 mm Hg; delta LVEDV, 4.2 +/- 3.0 ml, both p less than 0.05 versus control). At low cardiac volumes before dextran infusion, the intact pericardium did not affect the response to occlusion. By contrast, after dextran infusion in the presence of an intact pericardium, LVEDP significantly increased (delta, 6.4 +/- 3.6 mm Hg, p less than 0.05) but LVDEV did not (delta, 0.7 +/- 1.5 ml, p = NS). There was a parallel upward shift in the diastolic portion of the LV pressure-volume loop that was eliminated by removal of the pericardium. Thus, the change in LV diastolic pressure and volume during occlusion varied and depended on the baseline cardiac volume and presence of the pericardium. Before dextran infusion with the pericardium present and absent, coronary artery occlusion did not alter the LV diastolic chamber stiffness parameter, which was calculated from the diastolic interval of an averaged steady-state beat (0.040 +/- 0.019 versus 0.036 +/- 0.015 mm Hg/ml, p = NS). After dextran infusion with the pericardium present and absent, coronary artery occlusion increased the LV diastolic chamber stiffness parameter (0.057 +/- 0.034 and 0.074 +/- 0.034 mm Hg/ml, both p less than 0.05 versus controls, respectively). Vena caval occlusion eliminated the shifts in the diastolic portion of the LV pressure-volume loop with the pericardium present and absent.(ABSTRACT TRUNCATED AT 400 WORDS)Keywords
This publication has 14 references indexed in Scilit:
- Opposite initial effects of supply and demand ischemia on left ventricular diastolic compliance: The ischemia-diastolic paradoxJournal of Molecular and Cellular Cardiology, 1987
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984
- Ventricular diastolic pressure-volume shifts during acute ischemic left ventricular failure in dogsJournal of the American College of Cardiology, 1984
- Acute alterations in left ventricular diastolic chamber stiffness. Role of the "erectile" effect of coronary arterial pressure and flow in normal and damaged hearts.Circulation Research, 1982
- Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheterCardiovascular Research, 1981
- The pericardium and cardiac functionProgress in Cardiovascular Diseases, 1979
- The pericardium substantially affects the left ventricular diastolic pressure-volume relationship in the dog.Circulation Research, 1978
- Hemodynamic determinants of the time-course of fall in canine left ventricular pressure.Journal of Clinical Investigation, 1976
- Regional Myocardial Function during Acute Coronary Artery Occlusion and Its Modification by Pharmacologic Agents in the DogCirculation Research, 1974
- An Analysis of Segmental Ischemic Dysfunction Utilizing the Pressure-Length LoopCirculation, 1974