Spiral CT image deblurring for cochlear implantation
- 1 April 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 17 (2) , 251-262
- https://doi.org/10.1109/42.700737
Abstract
Cochlear implantation is the standard treatment for profound hearing loss. Preimplantation and postimplantation spiral computed tomography (CT) is essential in several key clinical and research aspects. The maximum image resolution with commercial spiral CT scanners is insufficient to define clearly anatomical features and implant electrode positions in the inner ear. In this paper, we develop an expectation-maximization (EM)-like iterative deblurring algorithm to achieve spiral CT image super-resolution for cochlear implantation, assuming a spatially invariant linear spiral CT system with a three-dimensional (3-D) separable Gaussian point spread function (PSF). We experimentally validate the 3-D Gaussian blurring model via phantom measurement and profile fitting. The imaging process is further expressed as convolution of an isotropic 3-D Gaussian PSF and a blurred underlying volumetric image. Under practical conditions, an oblique reconstructed section is approximated as convolution of an isotropic two-dimensional (2-D) Gaussian PSF and the corresponding actual cross section. The spiral CT image deblurring algorithm is formulated with sieve and resolution kernels for suppressing noise and edge artifacts. A typical cochlear cross section is used for evaluation, demonstrating a resolution gain up to 30%40% according to the correlation criterion. Physical phantoms, preimplantation and postimplantation patients are reconstructed into volumes of 0.1-mm cubic voxels. The patient images are digitally unwrapped along the central axis of the cochlea and the implanted electrode array respectively, then oblique sections orthogonal to the central axis formed. After deblurring, representation of structural features is substantially improved in all the cases.Keywords
This publication has 22 references indexed in Scilit:
- Block-iterative methods for image reconstruction from projectionsIEEE Transactions on Image Processing, 1996
- Unwrapping cochlear implants by spiral CTIEEE Transactions on Biomedical Engineering, 1996
- Roughness penalties on finite domainsIEEE Transactions on Image Processing, 1995
- Longitudinal image deblurring in spiral CT.Radiology, 1994
- The role of temporal bone imaging in cochlear implantsCurrent Opinion in Otolaryngology & Head and Neck Surgery, 1994
- Longitudinal resolution in volumetric x-ray computerized tomography-Analytical comparison between conventional and helical computerized tomographyMedical Physics, 1994
- A Comparison of Conventional and Spiral CTJournal of Computer Assisted Tomography, 1994
- Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.Radiology, 1990
- Results of a Comparative Study of a Reconstruction Procedure for Producing Improved Estimates of Radioactivity Distributions in Time-of-Flight Emission TomographyIEEE Transactions on Nuclear Science, 1984
- Physiological Age-Dependant Loss of Hearing and PresbyacusisInternational Audiology, 1966