Simplified Volumetric Flow Cytometry Allows Feasible and Accurate Determination of Cd4 T Lymphocytes in Immunodeficient Patients Worldwide
- 1 April 2004
- journal article
- research article
- Published by SAGE Publications in Antiviral Therapy
- Vol. 9 (3) , 395-405
- https://doi.org/10.1177/135965350400900309
Abstract
The determination of CD4 cells is of crucial clinical importance for patients with AIDS. However, the high costs involved represent limitations for CD4 cell counting in developing countries. In order to provide an affordable technique, we introduced a simplified volumetric counting (SVC) technique without sample manipulations and investigated it in a multicentre study. Blood samples from 434 healthy donors and immunodeficient patients were tested in eight hospital laboratories in Europe, Africa and Asia. CD4 cell counts were compared using inhouse flow cytometric methods and the SVC technique. The SVC method was performed on a low-cost flow cytometer (CyFlow SL, Partec, Münster, Germany) after 15 min antibody incubation without pre-analytic manipulations, such as washing or erythrocyte lysing procedures. Linear regression analysis demonstrated a correlation of r=0.942 (Europe), r=0.952 (Africa) and r=0.989 (Asia) between the SVC technique and the in-house methods. Bland Altman plot analysis of all patient data showed a mean bias between the two methods of +26 CD4 cells in favour of the SVC technique (measured range: 6–1905 cells/μl; median CD4 cell count: 388/μl). Three centres used the FACS-count technique (Becton-Dickinson, San José, Calif., USA) as an in-house method dispensing with pre-analytic manipulations. The comparison of SVC and FACS-count method revealed a mean bias of +32 CD4 cells/μl (median CD4 cell count: 349/μl). The accuracy of the SVC was tested on standards with known CD4 cell counts ( n=6) and was shown to be 95.2%. The low-cost device and the simplified no-lyse, no-wash test procedure reduces the costs per determination and facilitates the use of flow cytometry in developing countries.Keywords
This publication has 44 references indexed in Scilit:
- Successful implementation of a low-cost method for enumerating CD4+ T lymphocytes in resource-limited settingsAIDS, 2003
- A multicolor, no‐lyse no‐wash assay for the absolute counting of CD34+ cells by flow cytometryCytometry, 2002
- T‐cell subset counting and the fight against AIDS: Reflections over a 20‐year struggleCytometry, 2002
- Grading of laboratories on CD4+ T‐lymphocyte evaluations based on acceptable data boundaries defined by the measurement errorCytometry, 2002
- The HIV/AIDS Pandemic: A Sign of Instability in a Complex Global SystemJournal of Medicine and Philosophy, 2002
- Affordable Access to Essential Medication in Developing Countries: Conflicts Between Ethical and Economic Imperatives1Journal of Medicine and Philosophy, 2002
- Evaluation of TruCount Absolute-Count Tubes for Determining CD4 and CD8 Cell Numbers in Human Immunodeficiency Virus-Positive AdultsClinical and Diagnostic Laboratory Immunology, 2000
- Automatic volumetric capillary cytometry for counting white cells in white cell‐reduced plateletpheresis componentsTransfusion, 1997
- Standardization of absolute CD4+ lymphocyte counts across laboratories: An evaluation of the ortho CytoronAbsolute flow cytometry system on normal donorsCytometry, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986