Abstract
Sealing the arterial puncture site with a vascular hemostasis device has the potential to maintain optimal anticoagulation after stent implantation. The level of heparinization during the first 3 days after successful stent implantation was retrospectively compared between 2 groups of medically treated patients with (group A; n = 18) and without (group B; n = 17) a Vasoseal™ after sheath removal. The number of APTTs sampled in group A and B was 233 and 168, respectively. Respective mean values of APTT (seconds) in group A and B were 180 ± 79 and 172 ± 91 at day 1 (p = NS), 132 ± 43 and 125 ± 61 at day 2 (p = NS) and 123 ± 36 and 116 ± 48 at day 3 (p = NS). More APTTs were suboptimal (< 80 secs) in group B (34/168; 20%) compared to group A (17/233; 7%) [p < 0.001]. More patients in group B compared to group A had 1 or more (14/17; 82% vs. 8/18; 44%; p = 0.04), 2 or more (10/17; 59% versus 3/18; 17%; p = 0.02) and 3 or more (8/17; 47% vs. 2/18; 11%; p = 0.03) suboptimal APTTs. Bleeding complications were seen in 4 patients without and in 3 patients with a Vasoseal™. Thus application of a vascular hemostasis device results in a less variable anticoagulation after coronary stenting, but it does not abolish entry site‐related bleeding complications.© 1993 Wlley‐Liss, IncKeywords
This publication has 8 references indexed in Scilit:
- Percutaneous transradial artery approach for coronary stent implantationCatheterization and Cardiovascular Diagnosis, 1993
- Coronary stenting through 6 French guiding cathetersCatheterization and Cardiovascular Diagnosis, 1993
- Electrophysiological effects of myocardial stretch and mechanical determinants of stretch-activated arrhythmias.Circulation, 1992
- Angiographic and clinical outcome of intracoronary stenting: Immediate and long-term results from a large single-center experienceJournal of the American College of Cardiology, 1992
- Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study.Circulation, 1991
- Emergency stenting for refractory acute coronary artery occlusion during coronary angioplastyThe American Journal of Cardiology, 1990
- Emergency stenting for acute occlusion after coronary balloon angioplasty.Circulation, 1988
- Influence of balloon size on initial success, acute complications, and restenosis after percutaneous transluminal coronary angioplasty. A prospective randomized study.Circulation, 1988