Educating Families on Real Time Continuous Glucose Monitoring
Open Access
- 1 January 2009
- journal article
- research article
- Published by SAGE Publications in The Diabetes Educator
- Vol. 35 (1) , 124-135
- https://doi.org/10.1177/0145721708325157
Abstract
Purpose The purpose of this article is to describe the process of educating families and children with type 1 diabetes on real time continuous glucose monitoring (RT-CGM) and to note the similarities and differences of training patients using continuous subcutaneous insulin infusion (CSII) versus multiple daily injections (MDI). Methods A total of 30 CSII participants and 27 MDI participants were educated using the Navigator RT-CGM in a clinical trial. Time spent with families for visits and calls was tracked and compared between patient groups. The Diabetes Research in Children Network (DirecNet) educators were surveyed to assess the most crucial, time intensive, and difficult educational concepts related to CGM. Results Of the 27 MDI families, an average of 9.6 hours was spent on protocol-prescribed visits and calls (not measured in CSII) and 2 hours on participant-initiated contacts over 3 months. MDI families required an average of 5.4 more phone contacts over 3 months than CSII families. According to the DirecNet educators, lag time and calibrations were the most crucial teaching concepts for successful RT-CGM use. The most time was spent on teaching technical aspects, troubleshooting, and insulin dosing. The most unanticipated difficulties were skin problems including irritation and the sensor not adhering well. Conclusion Educators who teach RT-CGM should emphasize lag time and calibration techniques, technical device training, and sensor insertion. Follow-up focus should include insulin dosing adjustments and skin issues. The time and effort required to introduce RT-CGM provided an opportunity for the diabetes educators to reemphasize good diabetes care practices and promote self-awareness and autonomy to patients and families.This publication has 11 references indexed in Scilit:
- FreeStyle Navigator Continuous Glucose Monitoring System Use in Children With Type 1 Diabetes Using Glargine-Based Multiple Daily Dose RegimensDiabetes Care, 2008
- Use of the DirecNet Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the FreeStyle Navigator)Pediatric Diabetes, 2008
- Continuous Glucose Monitoring in Children with Type 1 DiabetesThe Journal of Pediatrics, 2007
- The Accuracy of the FreeStyle Navigator Continuous Glucose Monitoring System in Children With Type 1 DiabetesDiabetes Care, 2007
- Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetesPediatric Diabetes, 2006
- Eight-Point Glucose Testing Versus the Continuous Glucose Monitoring System in Evaluation of Glycemic Control in Type 1 DiabetesJournal of Clinical Endocrinology & Metabolism, 2005
- A Randomized Multicenter Trial Comparing the GlucoWatch Biographer With Standard Glucose Monitoring in Children With Type 1 DiabetesDiabetes Care, 2005
- Accuracy of the Modified Continuous Glucose Monitoring (CGMS®) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) StudyDiabetes Technology & Therapeutics, 2005
- Timing of Changes in Interstitial and Venous Blood Glucose Measured With a Continuous Subcutaneous Glucose SensorDiabetes, 2003
- The Accuracy of the GlucoWatch®G2™Biographer in Children with Type 1 Diabetes: Results of the Diabetes Research in Children Network (DirecNet) Accuracy StudyDiabetes Technology & Therapeutics, 2003