Hemodynamic Consequences of Thoracic Artificial Lung Attachment Configuration: A Computational Model
- 1 January 2007
- journal article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 53 (1) , 50-64
- https://doi.org/10.1097/01.mat.0000249867.39647.43
Abstract
A thoracic artificial lung (TAL) is being developed to assist treatment of acute and chronic pulmonary dysfunction. The TAL is attached directly to the pulmonary circulation. Depending on pathophysiology, the TAL may be attached in series with the natural lungs (NLs), in parallel with the NLs, or in an intermediate, hybrid configuration. We developed a computational model to study hemodynamic consequences of TAL attachment configuration under pathologic conditions. The pulmonary and systemic circulations, heart, and TAL are modeled as interconnected compliances and conductances, some valved. Time-varying cardiac compliance drives the system and generates pressures and flow rates. The model includes blood pressure feedback from the sympathetic nervous system, renin-angiotensin system, and renal volume control mechanism. We used previously published results from porcine experiments to verify model accuracy. We modeled normal physiology and four disease states. A hybrid configuration with 100% cardiac output through the TAL and 40% through the NLs would deliver maximal blood flow, 3.6 to 4.6 l/min, to the TAL and be tolerated by the right ventricle. Additionally, the model suggests that reducing the large "minor loss" resistances at the graft anastomoses to the pulmonary artery would improve the hemodynamics of all TAL attachment configurations.Keywords
This publication has 28 references indexed in Scilit:
- Hemodynamic and Gas Transfer Properties of a Compliant Thoracic Artificial LungAsaio Journal, 2005
- In Vivo Hemodynamic Responses to Thoracic Artificial Lung AttachmentAsaio Journal, 2005
- The paracorporeal artificial lung improves 5-day outcomes from lethal smoke/burn-induced acute respiratory distress syndrome in sheepThe Annals of Thoracic Surgery, 2002
- Platelets inhibit the lysis of pulmonary microemboliAmerican Journal of Physiology-Lung Cellular and Molecular Physiology, 2002
- Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulationThe Annals of Thoracic Surgery, 2001
- Development of an Ambulatory Artificial Lung in an Ovine Survival ModelAsaio Journal, 2001
- Outcome of Patients With Idiopathic Pulmonary Fibrosis Admitted to the ICU for Respiratory FailureChest, 2001
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2000
- HEMODYNAMIC AND HUMORAL CONDITIONS IN VARIOUS QUANTITY OF REDUCED PULMONARY BLOOD FLOW DURING VENOARTERIAL BYPASS IN AWAKE GOATSAsaio Journal, 1997
- Testing of an Intrathoracic Artificial Lung in a Pig ModelPublished by Wolters Kluwer Health ,1996