A transpulmonary contrast medium enhances the transcranial Doppler signal in humans.
- 1 December 1993
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Stroke
- Vol. 24 (12) , 1903-1909
- https://doi.org/10.1161/01.str.24.12.1903
Abstract
Transtemporal insonation in transcranial Doppler sonography is often impaired by an insufficient signal-to-noise ratio, especially in elderly patients. A transpulmonary stable air microbubble suspension was injected intravenously in humans as an intracranial ultrasonic contrast agent. In a clinical phase II study, 20 patients (15 women, 5 men; mean age, 65.5 +/- 11.5 years) presenting with clinical indications for transcranial Doppler investigation were examined. A total of 97 intravenous injections with different concentrations (200, 300, and 400 mg/mL of suspension) of air microbubbles bound to galactose microparticles as a carrier were performed. The signal enhancement of color-coded pulse curves of basal cerebral arteries was evaluated off-line in comparison to an integrated color-coded decibel scale, considering quality, quantity, and time course of enhancement requiring a 3-dB level above the native signal. The overall diagnostic information was assessed according to a reliability score. The first acoustic signal increase was registered after an average of 21 seconds. Time intervals for a dose-dependent peak intensity and maximal duration were 41.3 +/- 17.1 seconds and 118.0 +/- 69.8 seconds (200 mg/mL); 55.5 +/- 27.7 seconds and 237.0 +/- 112.3 seconds (300 mg/mL); and 66.1 +/- 31.8 seconds and 293.0 +/- 122.0 seconds (400 mg/mL), respectively. Duration of signal enhancement increased significantly (P < .05) with higher concentrations. The extent of signal enhancement during the whole pulse curve reached an average of 9.1 +/- 5.0 dB for 200 mg/mL, 12.0 +/- 5.4 dB for 300 mg/mL (significant on P < .05 level), and 13.1 +/- 5.6 dB for 400 mg/mL concentration (P = NS). Respective maximal intensity spots reached 17.5 +/- 6.0, 20.7 +/- 5.5, and 22.7 +/- 5.9 dB for increasing concentrations, respectively. Overall visual assessment of enhanced pulse curves for diagnostic reliability showed a sufficient result in 38.1% of all injections with 200 mg/mL, in 88.6% with 300 mg/mL, and in 84.2% with 400 mg/mL concentration. Minimal side effects occurring in 12.4% of all injections were all reversible. Transpulmonary stable air microbubbles bound to a galactose carrier represent a useful and safe contrast agent in case of an insufficient native signal in transcranial Doppler investigation.Keywords
This publication has 14 references indexed in Scilit:
- Principles and recent developments in ultrasound contrast agentsUltrasonics, 1991
- Farbkodierte Duplexsonographie und Ultraschallkontrastmittel - Nachweis von renalen Perfusionsdefekten im TierexperimentRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1991
- Intravenous contrast echocardiography with use of sonicated albumin in humans: Systolic disappearance of left ventricular contrast after transpulmonary transmissionJournal of the American College of Cardiology, 1990
- Contrast agents for diagnostic ultrasound: development and evaluation of polymer-coated microbubblesBiomaterials, 1990
- Safety and efficacy of a new transpulmonary ultrasound contrast agent: Initial multicenter clinical resultsJournal of the American College of Cardiology, 1990
- Contrast agents in diagnostic ultrasoundUltrasound in Medicine & Biology, 1989
- Transcranial Dopplersonography. Examination technique and normal reference valuesUltrasound in Medicine & Biology, 1986
- Transmission of Ultrasound Through the Temporal BonePublished by Springer Nature ,1986
- The safety of contrast echocardiography: Report of the committee on contrast echocardiography for the American Society of EchocardiographyJournal of the American College of Cardiology, 1984
- The source of ultrasound contrast effectJournal of Clinical Ultrasound, 1980