Determination of 99mTc‐DTPA clearance by a single plasma sample method
- 1 December 1986
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 6 (6) , 579-588
- https://doi.org/10.1111/j.1475-097x.1986.tb00790.x
Abstract
To derive a formula for determnation of 99mTc-DTPA clearance (Cl) from the radioactivity in a single plasma sample, the relation Cl=ECV/.hivin.t was used, where ECV is the extracellular volume and .hivin.t is the mean transit time of the tracer in the organism. By studying the 99mTc-DTPA time activity curves of 45 consecutive patients we found that ECV could be estimated from the body surface area, and that .hivin.t could be calculated from the radioactivity in a single plasma sample. Cl calculated by the single sample method was almost identical to Cl calculated by a standard multiple sample method (r=0.987). It is concluded that the single sample method is accurate and that it may prove useful as a routine method provided that (a) the method is not used in patients with 99mTc-DTPA clearance less than 30 ml min-1, since this investigation includes only patients with Cl > 30 ml min-1; (b) the method is not used for children, since the test material did not contain any children; (c) the method is only used for plasma samples drawn at 180 .ltoreq. t .ltoreq. 300 min.This publication has 9 references indexed in Scilit:
- Calculation of 51Cr‐EDTA clearance in children from the activity in one plasma sample by transformation of the biexponential plasma time‐activity curve into a monoexponential with identical integral area below the time‐activity curveClinical Physiology and Functional Imaging, 1984
- 51Cr‐EDTA clearance determined by one plasma sample in childrenClinical Physiology and Functional Imaging, 1984
- A method for the calculation of renal clearance based on a single plasma sampleClinical Physiology and Functional Imaging, 1983
- COMPARISON OF 4 COMMERCIAL TC-99M(SN)DTPA PREPARATIONS USED FOR THE MEASUREMENT OF GLOMERULAR-FILTRATION RATE - CONCISE COMMUNICATION1980
- The glomerular filtration rate determined with993Tc-DTPA and a portable cadmium telluride detectorScandinavian Journal of Clinical and Laboratory Investigation, 1978
- A Simple Method for Accurate Assessment of the Glomerular Filtration Rate in ChildrenScandinavian Journal of Clinical and Laboratory Investigation, 1974
- A Simple Method for the Determination of Glomerular Filtration RateScandinavian Journal of Clinical and Laboratory Investigation, 1972
- Volumes of Distribution and Clearances of Intravenously Injected Creatinine in the DogAmerican Journal of Physiology-Legacy Content, 1955