Output voltage waveform improvement of the coaxial Marx-type high-voltage generator
- 1 December 1985
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 56 (12) , 2287-2289
- https://doi.org/10.1063/1.1138366
Abstract
A metal ring was installed to each of the main capacitor modules of the coaxial Marx-type high-voltage generator to increase the stray capacitance between the main capacitors and the cylinder of the outer conductor. Improvements in build-up time of the output voltage were achieved and good agreements were obtained between the experimental and the simulated results.Keywords
This publication has 7 references indexed in Scilit:
- Atmospheric pressure operation of an electron beam excited KrF laser using Kr/F2 mixturesApplied Physics Letters, 1984
- A tabletop relativistic electron beam generatorJournal of Vacuum Science & Technology A, 1983
- Porous tungsten relativistic electron beam cathodes compared with carbon cathodesReview of Scientific Instruments, 1983
- Design charts for Tesla-transformer-type relativistic electron beam generatorsReview of Scientific Instruments, 1982
- Study of the Rectangular-Like Output Waveforms of a 720 kV Coaxial Marx GeneratorJapanese Journal of Applied Physics, 1981
- Compression System in ERA of IPP-Japan. II. Experimental ResultJapanese Journal of Applied Physics, 1980
- Coaxial Marx Generator for Producing Intense Relativistic Electron BeamsJapanese Journal of Applied Physics, 1974