Commutability of control materials in glycohemoglobin determinations
- 1 March 1998
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 44 (3) , 632-638
- https://doi.org/10.1093/clinchem/44.3.632
Abstract
The intermethod variabilities of control materials and patient blood samples for the measurement of glycohemoglobin were compared. Sets of 50 blood samples and 15 control materials were analyzed by HPLC and affinity and immunochemical methods. For each pair of methods, the distances of the materials from the regression line of patient blood results (expressed as normalized residuals) were calculated. Only two of 15 controls had normalized residuals exceeding 3 standard deviations from the regression line. Total hemoglobin (Hb) content, Hb derivatives, and cellulose acetate electrophoresis demonstrated that only a minority of controls could be considered similar to patients’ blood samples. We selected Menarini’s and our home-prepared controls to simulate calibration of the different techniques by these materials. Intermethod calibration succeeded mostly in harmonizing results obtained by HPLC methods. On the contrary, calibration of the immunochemical techniques (Boehringer and Roche) did not improve intermethod agreement to a clinically useful level.This publication has 15 references indexed in Scilit:
- Another Step Toward Standardization of Methods for Measuring Hemoglobin A1cClinical Chemistry, 1997
- Candidate reference methods for hemoglobin A1c based on peptide mappingClinical Chemistry, 1997
- Electrospray Mass Spectrometry for Measurement of GlycohemoglobinClinical Chemistry, 1997
- Glycohemoglobin assays evaluated in a large-scale quality-control surveyClinical Chemistry, 1995
- Determination of alpha-amylase activity: methods comparison and commutability study of several control materialsClinical Chemistry, 1995
- Three assays for glycohemoglobin comparedClinical Chemistry, 1995
- Automated determination of glycated hemoglobin: Comparative evaluation of five assay systemsJournal of Clinical Laboratory Analysis, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- Commutability of control materials in cholesterol measurementScandinavian Journal of Clinical and Laboratory Investigation, 1993
- Characterization and intermethod relationships of materials containing purified human pancreatic and salivary amylase.Clinical Chemistry, 1981