MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility
- 25 March 2003
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 30 (4) , 583-589
- https://doi.org/10.1118/1.1562169
Abstract
Preclinical experiments are carried out with ∼20–30 μm wide, ∼10 mm high parallel microbeams of hard, broad‐“white”‐spectrum x rays (∼50–600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate and/or unsafe. Novel physical microdosimetry (implemented with MOSFET chips in the “edge‐on” mode) and Monte Carlo computer‐simulated dosimetry are described here for selected points in the peak and valley regions of a microbeam‐irradiated tissue‐equivalent phantom. Such microbeam irradiation causes minimal damage to normal tissues, possible because of rapid repair of their microscopic lesions. Radiation damage from an array of parallel microbeams tends to correlate with the range of peak‐valley dose ratios (PVDR). This paper summarizes comparisons of our dosimetric MOSFET measurements with Monte Carlo calculations. Peak doses at depths 22 mm and valley doses at all depths investigated (2 mm–62 mm) are within 2–13 % of the Monte Carlo values. These results lend credence to the use of MOSFET detector systems in edge‐on mode for microplanar irradiation dosimetry.Keywords
This publication has 22 references indexed in Scilit:
- Feasibility study of online high-spatial-resolution MOSFET dosimetry in static and pulsed x-ray radiation fieldsIEEE Transactions on Nuclear Science, 2001
- Physics study of microbeam radiation therapy with PSI‐version of Monte Carlo code GEANT as a new computational toolMedical Physics, 2000
- Improved spatial resolution by MOSFET dosimetry of an x‐ray microbeamMedical Physics, 2000
- MOSFET dosimetry of an X-ray microbeamIEEE Transactions on Nuclear Science, 1999
- XOP: recent developmentsPublished by SPIE-Intl Soc Optical Eng ,1998
- XOP: A graphical user interface for spectral calculations and x-ray optics utilitiesReview of Scientific Instruments, 1996
- MOSFET dosimeters: the role of encapsulation on dosimetric characteristics in mixed gamma-neutron and megavoltage X-ray fieldsIEEE Transactions on Nuclear Science, 1995
- Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.Proceedings of the National Academy of Sciences, 1995
- Microbeam radiation therapyMedical Physics, 1992
- Whole-pattern fitting in energy-dispersive powder diffractionJournal of Applied Crystallography, 1992