Rapid high‐resolution T1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
Top Cited Papers
Open Access
- 31 January 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (3) , 566-574
- https://doi.org/10.1002/mrm.20791
Abstract
Rapid 3D mapping of T1 relaxation times is valuable in diverse clinical applications. Recently, the variable flip angle (VFA) spoiled gradient recalled echo approach was shown to be a practical alternative to conventional methods, providing better precision and speed. However, the method is known to be sensitive to transmit field (B1+) inhomogeneity and can result in significant systematic errors in T1 estimates, especially at high field strengths. The main challenge is to improve the accuracy of the VFA approach without sacrificing speed. In this article, the VFA method was optimized for both accuracy and precision by considering the influence of imperfect transmit fields, noise bias, and selection of flip angles. An analytic solution was developed for systematic B1+-induced T1 errors and allows simple correction of T1 measurements acquired with any imaging parameters. A noise threshold was also identified and provided a guideline for avoiding T1 biases. Finally, it was shown that three flip angles were the most efficient for maintaining accuracy and high precision over large ranges of T1. A rapid B1+ mapping sequence was employed in all phantom experiments and high-field in vivo brain scans. Experimental results confirmed the theory and validated the accuracy of the proposed method. Magn Reson Med, 2006.Keywords
This publication has 24 references indexed in Scilit:
- T1, T2 relaxation and magnetization transfer in tissue at 3TMagnetic Resonance in Medicine, 2005
- In vivo method for correcting transmit/receive nonuniformities with phased array coilsMagnetic Resonance in Medicine, 2005
- Determination of optimal angles for variable nutation proton magnetic spin‐lattice, T1, and spin‐spin, T2, relaxation times measurementMagnetic Resonance in Medicine, 2003
- Dynamic T1 estimation of brain tumors using double‐echo dynamic MR imagingJournal of Magnetic Resonance Imaging, 2003
- T1 quantification with inversion recovery TrueFISPMagnetic Resonance in Medicine, 2001
- Practical Implementation and Optimization of One‐shot T1 imagingMagnetic Resonance in Medicine, 1991
- A comparison of one‐shot and recovery methods in T1 imagingMagnetic Resonance in Medicine, 1988
- An analysis of fast imaging sequences with steady‐state transverse magnetization refocusingMagnetic Resonance in Medicine, 1988
- Conditions for the driven equilibrium single pulse observation of spin-lattice relaxation timesJournal of Magnetic Resonance (1969), 1987
- Driven-equilibrium single-pulse observation of T1 relaxation. A reevaluation of a rapid “new” method for determining NMR spin-lattice relaxation timesJournal of Magnetic Resonance (1969), 1985