Dynamic T1 estimation of brain tumors using double‐echo dynamic MR imaging
Open Access
- 13 June 2003
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (1) , 113-120
- https://doi.org/10.1002/jmri.10331
Abstract
Purpose: To assess the clinical utility of a new method for real‐time estimation of T1 during the first pass of contrast agent by using this method to examine brain tumors.Materials and Methods: The multi‐phase spoiled gradient‐echo pulse sequence using the double‐echo magnetic resonance (MR) technique was modified. In the first half of the pulse sequence, the flip angle was varied systematically. Then, static T1 values were calculated using differences in MR signal intensities between different flip angles. In the latter half of this sequence, changes in absolute T1 were calculated using differences in signal intensities before and after injection of contrast agent. The double‐echo MR data were used to minimize the T2* effect. Five cases of neurinoma and seven cases of meningioma were examined. Changes in T1 during the first pass of contrast agent were compared between neurinoma and meningioma.Results: Changes in absolute T1 were clearly demonstrated on the parametric map. Although the changes in absolute T1 during the first pass of contrast agent did not allow differentiation between the two types of tumors, the mean gradient after the first pass was statistically higher for neurinoma than for meningioma (P < 0.05; meningioma, 0.011 ± 0.012 second−1/second; neurinoma, 0.034 ± 0.020 second−1/second).Conclusion: The present method appears to be useful for estimation of dynamic T1 changes in brain tumors in clinical settings. J. Magn. Reson. Imaging 2003;18:113–120.Keywords
This publication has 18 references indexed in Scilit:
- Vascular Permeability: Quantitative Measurement with Double-Echo Dynamic MR Imaging—Theory and Clinical ApplicationRadiology, 2000
- Optimization of the ultrafast look-locker echo-planar imaging T1 mapping sequenceMagnetic Resonance Imaging, 1998
- Dual dynamic contrast‐enhanced MR imagingJournal of Magnetic Resonance Imaging, 1997
- Vascularity of meningiomas and neuromas: assessment with dynamic susceptibility-contrast MR imaging.American Journal of Roentgenology, 1994
- Studies of Gd‐DTPA relaxivity and proton exchange rates in tissueMagnetic Resonance in Medicine, 1994
- Spin‐lattice relaxation time measurement by means of a TurboFLASH techniqueMagnetic Resonance in Medicine, 1993
- Perfusion imaging with NMR contrast agentsMagnetic Resonance in Medicine, 1990
- Optimizing the precision in T1 relaxation estimation using limited flip anglesMagnetic Resonance in Medicine, 1987
- Rapid calculation of T1 using variable flip angle gradient refocused imagingMagnetic Resonance Imaging, 1987
- Differentiation of Cerebellopontine Angle Neuromas and Meningiomas with MR ImagingJournal of Computer Assisted Tomography, 1985