Electroporator with automatic change of electric field direction improves gene electrotransfer in-vitro
Open Access
- 2 July 2007
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 6 (1) , 25
- https://doi.org/10.1186/1475-925x-6-25
Abstract
Gene electrotransfer is a non-viral method used to transfer genes into living cells by means of high-voltage electric pulses. An exposure of a cell to an adequate amplitude and duration of electric pulses leads to a temporary increase of cell membrane permeability. This phenomenon, termed electroporation or electropermeabilization, allows various otherwise non-permeant molecules, including DNA, to cross the membrane and enter the cell. The aim of our research was to develop and test a new system and protocol that would improve gene electrotransfer by automatic change of electric field direction between electrical pulses. For this aim we used electroporator (EP-GMS 7.1) and developed new electrodes. We used finite-elements method to calculate and evaluate the electric field homogeneity between these new electrodes. Quick practical test was performed on confluent cell culture, to confirm and demonstrate electric field distribution. Then we experimentally evaluated the effectiveness of the new system and protocols on CHO cells. Gene transfection and cell survival were evaluated for different electric field protocols. The results of in-vitro gene electrotransfer experiments show that the fraction of transfected cells increases by changing the electric field direction between electrical pulses. The fluorescence intensity of transfected cells and cell survival does not depend on electric field protocol. Moreover, a new effect a shading effect was observed during our research. Namely, shading effect is observed during gene electrotransfer when cells are in clusters, where only cells facing negative electro-potential in clusters become transfected and other ones which are hidden behind these cells do not become transfected. On the basis of our results we can conclude that the new system can be used in in-vitro gene electrotransfer to improve cell transfection by changing electric field direction between electrical pulses, without affecting cell survival.Keywords
This publication has 36 references indexed in Scilit:
- New insights in the visualization of membrane permeabilization and DNA/membrane interaction of cells submitted to electric pulsesBiochimica et Biophysica Acta (BBA) - General Subjects, 2005
- The future of gene therapyNature, 2004
- Gene Therapy Insertional Mutagenesis InsightsScience, 2004
- Gene Therapy--New Challenges AheadScience, 2003
- LMO2 -Associated Clonal T Cell Proliferation in Two Patients after Gene Therapy for SCID-X1Science, 2003
- Electroporation: theory and methods, perspectives for drug delivery, gene therapy and researchActa Physiologica Scandinavica, 2003
- Progress and prospects: naked DNA gene transfer and therapyGene Therapy, 2003
- Fundamentals of electroporative delivery of drugs and genesBioelectrochemistry and Bioenergetics, 1999
- In vivo gene electroinjection and expression in rat liverFEBS Letters, 1996
- A study of magnetic field effects on fibroblast cultures part 3. The evaluation of the effects of static and extremely low frequency (ELF) magnetic fields on glycosaminoglycan metabolism in fibroblasts, cell coats and culture mediumBioelectrochemistry and Bioenergetics, 1996