Fatigue crack propagation behavior of ultrahigh molecular weight polyethylene
- 1 January 1984
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 2 (2) , 119-125
- https://doi.org/10.1002/jor.1100020202
Abstract
The relative fatigue crack propagation resistance of plain and carbon fiber‐reinforced ultrahigh molecular weight polyethylene (UHMWPE) was determined from cyclic loading tests performed on compact tension specimens machined from the tibial components of total knee prostheses. Both materials were characterized by dynamic mechanical spectroscopy, X‐ray diffraction, and differential scanning calorimetry. The cyclic tests used loading in laboratory air at 5 Hz using a sinusoidal wave form. Dynamic mechanical spectroscopy showed that the reinforced UHMWPE had a higher elastic storage modulus than the plain UHMWPE, whereas X‐ray diffraction and differential scanning calorimetry showed that the percent crystallinity and degree of order in the crystalline regions were similar for the two materials. Fatigue crack propagation in both materials proved to be very sensitive to small changes in the applied cyclic stress intensity range. A 10% increase in stress intensity resulted in approximately an order of magnitude increase in fatigue crack growth rate. The fatigue crack propagation resistance of the reinforced UHMWPE was found to be significantly worse than that of the plain UHMWPE. This result was attributed to poor bonding between the carbon fibers and the UHMWPE matrix and the ductile nature of the matrix itself.Keywords
This publication has 12 references indexed in Scilit:
- Fatigue Crack Propagation in Short-Fiber Reinforced PlasticsPublished by American Chemical Society (ACS) ,1984
- Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prosthesesJournal of Biomedical Materials Research, 1983
- Effect of short glass fibers and particulate fillers on fatigue crack propagation in polyamidesPolymer Engineering & Science, 1982
- Analysis of Material FailuresOrthopedic Clinics of North America, 1982
- The effect of carbon fiber reinforcement on contact area, contact pressure, and time‐dependent deformation in polyethylene tibial componentsJournal of Biomedical Materials Research, 1981
- Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening deviceJournal of Biomedical Materials Research, 1981
- Uniaxial tensile creep behaviour of ultra high molecular weight linear polyethylenePolymer, 1981
- Fracture of polyethylene acetabular cups. Report of two cases.Journal of Bone and Joint Surgery, 1979
- The fracture of ultrahigh molecular weight polyethylene in the human bodyJournal of Biomedical Materials Research, 1979
- Failure of total knee arthroplasty due to loosening and deformation of the tibial component.Journal of Bone and Joint Surgery, 1978