Myocardial T2 quantitation in patients with iron overload at 3 Tesla
Open Access
- 23 July 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (2) , 394-400
- https://doi.org/10.1002/jmri.21851
Abstract
Purpose To investigate the feasibility of measuring myocardial T2 at 3 Tesla for assessment of tissue iron in thalassemia major and other iron overloaded patients. Materials and Methods A single‐breathhold electrocardiogram‐triggered black‐blood multi‐echo spin‐echo (MESE) sequence with a turbo factor of 2 was implemented at 3 Tesla (T). Myocardial and liver T2 values were measured with three repeated breathholds in 8 normal subjects and 24 patients. Their values, together with the T2* values measured using a breathhold multi‐echo gradient‐echo sequence, were compared with those at 1.5T in the same patients. Results At 3T, myocardial T2 was found to be 39.6 ± 7.4 ms in normal subjects. In patients, it ranged from 12.9 to 50.1 ms. T2 and T2* were observed to correlate in heart (ρ = 0.93, ρ < 0.0001) and liver (P = 0.95, P < 0.0001). Myocardial T2 and T2* at 3T were also highly correlated with the 1.5T measurements. Preliminary results indicated that myocardial T2 quantitation was relatively insensitive to B1 variation, and reproducible with 3.2% intra‐exam and 3.8% inter‐exam variations. Conclusion Myocardial T2 quantitation is feasible at 3T. Given the substantially decreased T2* and increased B0 inhomogeneity, the rapid myocardial T2 measurement protocol demonstrated here may present a robust alternative to study cardiac iron overload at 3T. J. Magn. Reson. Imaging 2009;30:394–400.Keywords
This publication has 42 references indexed in Scilit:
- Breathhold multiecho fast spin‐echo pulse sequence for accurate R2 measurement in the heart and liverMagnetic Resonance in Medicine, 2009
- Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3TMagnetic Resonance in Medicine, 2008
- Multi-center transferability of a breath-hold T2 technique for myocardial iron assessmentJournal of Cardiovascular Magnetic Resonance, 2008
- R2* imaging of transfusional iron burden at 3T and comparison with 1.5TJournal of Magnetic Resonance Imaging, 2007
- MRI detects myocardial iron in the human heartMagnetic Resonance in Medicine, 2006
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- Improved R2* measurements in myocardial iron overloadJournal of Magnetic Resonance Imaging, 2005
- Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemiaJournal of Magnetic Resonance Imaging, 2003
- Double inversion black‐blood fast spin‐echo imaging of the human heart: A comparison between 1.5T and 3.0TJournal of Magnetic Resonance Imaging, 2003
- Multiecho imaging sequences with low refocusing flip anglesJournal of Magnetic Resonance (1969), 1988