Simultaneous measurement of glucose and glutamine in insect cell culture media by near infrared spectroscopy
- 5 July 1997
- journal article
- Published by Wiley in Biotechnology & Bioengineering
Abstract
The purpose of this study was to develop non-invasive techniques to monitor the composition of cell culture media in insect cell bioreactors. Such a monitor could be used in conjunction with a fed-batch feeding scheme to ensure that cells are maintained in an optimal environment for growth and protein production. Glucose and glutamine concentrations in an insect cell culture bioreactor were determined off-line with near-infrared (NIR) absorption spectroscopy. Spectra were collected from 5000 to 4000 cm(-1) with a 1.5-mm optical path length. Partial least squares (PLS) regression was applied to correlate the collected spectra with the concentration of the desired analytes. Under the culture conditions evaluated here, glucose and glutamine concentrations ranged from 38 to 55 mM and from 3 to 13 mM, respectively. Accurate measurements of glucose and glutamine in insect cell culture samples were possible over these entire ranges. The standard error of prediction (SEP) and mean percent error (MPE) for glutamine were 0.52 mM and 5.3%, respectively. Glucose could be measured with an SEP of 1.30 mM and an MPE of 2.3%. These levels of error are quite low considering the changing complexity of the growth media due to the shifting levels of amino acids, carbohydrates, yeastolate, proteins, and cell debris. This study represents an important step in the development of noninvasive on-line monitoring devices for cell culture bioreactors.Keywords
This publication has 12 references indexed in Scilit:
- Simultaneous Measurements of Glucose, Glutamine, Ammonia, Lactate, and Glutamate in Aqueous Solutions by Near-Infrared SpectroscopyApplied Spectroscopy, 1996
- Near-Infrared Spectroscopic Determination of Acetate, Ammonium, Biomass, and Glycerol in an Industrial Escherichia Coli FermentationApplied Spectroscopy, 1996
- The effect of oscillating dissolved oxygen concentrations on the metabolism of a Spodoptera frugiperda IPLB‐Sf21‐AE clonal isolateBiotechnology & Bioengineering, 1995
- Accuracy of the Ysi Stat Plus Analyzer for Glucose and LactateAnalytical Letters, 1995
- Simultaneous measurement of glucose and glutamine in aqueous solutions by near infrared spectroscopyApplied Biochemistry and Biotechnology, 1995
- A near‐infrarod spectroscopy technique for the control of fermentation processes: An application to lactic acid fermentationBiotechnology & Bioengineering, 1994
- Mathematical descriptions of hybridoma culture kinetics. III. Simulation of fed-batch bioreactorsJournal of Biotechnology, 1989
- Partial least-squares methods for spectral analyses. 1. Relation to other quantitative calibration methods and the extraction of qualitative informationAnalytical Chemistry, 1988
- Partial Least-Squares Quantitative Analysis of Infrared Spectroscopic Data. Part I: Algorithm ImplementationApplied Spectroscopy, 1988
- Sensitive and rapid amino acid analysis of peptide hydrolysates by high-performance liquid chromatography of o-phthaldialdehyde derivativesJournal of Chromatography A, 1982