Advantages of Evaporative Light Scattering Detection for the Purity Control of Commercial Cyclodextrins
- 1 April 1997
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 20 (7) , 1015-1035
- https://doi.org/10.1080/10826079708010955
Abstract
Using an Evaporative Light Scattering Detector (ELSD) which is a universal detection system compatible with gradient elution, allowed satisfactory analysis of the non volatile impurities in cyclodextrins. ELSD performances for cyclodextrin analysis were evaluated. The detection capabilities of ELSD are better than those of RI and Polarimetric detectors (detection thresholds obtained with the ELSD are about 80 ng). Analyses were performed on different Phenyl columns with acetonitrilewater mobile phases in isocratic or gradient mode. Potential impurities of β-CD and of TM-β-CD, which included 7 linear (glucose to maltoheptaose), 2 unbranched cyclic (α- and γ-CD) glucose polymers and partially methylated cyclodextrins, have been determined. As the ELSD response factors of these homologous compounds are highly similar, it is possible to evaluate impurity levels without previous identification. The methods presented provide good selectivity and sensitivity and can also be used to compare different sources of cyclodextrins.Keywords
This publication has 31 references indexed in Scilit:
- Studies on the behaviour of α-, β- and γ-cyclodextrins and some derivatives under reversed-phase liquid Chromatographic conditionsAnalytica Chimica Acta, 1995
- Analysis of oligosaccharides using aminobonded silica gel and a ternary eluent with evaporative light scattering detectionAnalytical and Bioanalytical Chemistry, 1995
- Some Pharmaceutical Properties of 2,3,6-partially Methylated-β- cyclodextrin and its Solubilizing and Stabilizing AbilitiesDrug Development and Industrial Pharmacy, 1994
- Quantification of trace levels of β‐cyclodextrin and substitution patterns in hydroxypropyl‐β‐cyclodextrin using high‐performance liquid chromatography with polarimetric detectionChirality, 1993
- Determination of the impurity profile of γ-cyclodextrin by high-performance liquid chromatographyJournal of Chromatography A, 1992
- Two high-performance liquid chromatographic columns for analyses of malto-oligosaccharidesJournal of Chromatography A, 1987
- Isolation and characterization of branched cyclodextrinsCarbohydrate Research, 1986
- The Use of Reverse-Phase Columns for Separation of Unsubstituted CarbohydratesJournal of Carbohydrate Chemistry, 1986
- High-performance liquid chromatographic separation of carbohydrate oligomersJournal of Chromatography A, 1981
- Separation of cyclodextrins by high-performance liquid chromatographyJournal of Chromatography A, 1979