To determine whether a ventricular (LV) end-systolic dimension (ESD) greater than or equal to 55 mm and LV left fractional shortening less than 25% are risk factors for aortic valve replacement (AVR) in patients with aortic insufficiency, we analyzed the clinical course and M-mode echocardiograms in 47 consecutive patients who underwent AVR for isolated symptomatic AI. Group 1 patients (n = 27) had a preoperative ESD less than 55 mm (mean 44 mm, range 30-52 mm) and group 2 patients (n = 20) had a preoperative ESD greater than or equal to 55 mm (mean 62 mm, range 55-85 mm). One patient in group 1 and 10 patients in group 2 had left ventricular fractional shortening less than 25%. There were no perioperative or postoperative deaths during an average follow-up of 41 months (range 6-76 months). Five patients had perioperative myocardial infarctions (MIs), three in group 1 and two in group 2. Since myocardial protection with cold potassium cardioplegia was instituted, no patient has suffered a perioperative MI. The average preoperative New York Heart Association functional classification was 2.3 (group 1) and 2.6 (group 2). Postoperatively, it was 1.2 in group 1 and 1.1 in group 2. Thirty-three patients (20 in group 1 and 13 in group 2) had echocardiograms at least 1 year after AVR. Of these, LV-end diastolic dimension decreased fro 67 +/- 6 to 53 +/- 6 mm (mean +/- SD) in group 1 (p less than 0.001) and from 79 +/- 3 to 55 +/- 6 mm in group 2 (p less than 0.001). The LVESD also decreased, but this is difficult to interpret because of frequent postoperative abnormal interventricular septal motion. The LV cross-sectional area, an index of LV mass, decreased in group 1 from 25 +/- 5 to 20 +/- 5 cm2 (p lss than 0.001) and in group 2 from 32 +/- 9 to 20 +/- 5 cm2 (p less than 0.001). Postoperative end-diastolic dimension and cross-sectional area were not significantly different between the two groups. We concluded that in aortic insufficiency, a preoperative ESD greater than or equal to 55 mm does not preclude successful AVR, as judged by long-term survival, symptomatic relief, and normalization of LV dimensions assessed by echocardiography.This publication has 14 references indexed in Scilit:
- Extent of myocardial damage after open-heart surgery assessed from serial plasma enzyme levels in either of two periods (1975 and 1980).Heart, 1982
- End-systolic volume as a predictor of postoperative left ventricular performance in volume overload from valvular regurgitationThe American Journal of Medicine, 1980
- Observations on the optimum time for operative intervention for aortic regurgitation. I. Evaluation of the results of aortic valve replacement in symptomatic patients.Circulation, 1980
- Limitations of echocardiography in the assessment of left ventricular size and function in aortic regurgitation.Circulation, 1980
- Impaired left ventricular function in chronic aortic valve disease: survival and function after replacement by Björk-Shiley prosthesis.Circulation, 1979
- Long-term follow-up after isolated aortic valve replacementThe Journal of Thoracic and Cardiovascular Surgery, 1977
- Evaluating techniques of myocardial preservation for aortic valve replacement: Operative riskThe Journal of Thoracic and Cardiovascular Surgery, 1976