Alternative acrylic bone cement formulations for cemented arthroplasties: Present status, key issues, and future prospects
- 22 June 2007
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 84B (2) , 301-319
- https://doi.org/10.1002/jbm.b.30873
Abstract
All the commercially available plain acrylic bone cement brands that are used in cemented arthroplasties are based on poly (methyl methacrylate) and, with a few exceptions, have the same constituents. It is well known that these brands are beset with many drawbacks, such as high maximum exotherm temperature, lack of bioactivity, and volumetric shrinkage upon curing. Furthermore, concerns have been raised about a number of the constituents, such as toxicity of the activator (N,N,dimethyl‐p‐toluidine) and possible involvement of the radiopacifier (BaSO4 or ZrO2 particles) in third‐body wear. Thus, over the years, many research efforts have been expended to address these drawbacks, culminating in a large number of alternative formulations, which may be grouped into 16 categories. Although there are a number of reviews of the large literature that now exists on these formulations, each covers only some of the categories and none contains a detailed discussion of the germane issues. The objective of the present work, therefore, was to present a comprehensive and critical review of the whole field. In addition to succinct descriptions of the cements in each category, there are explicative summaries of literature reports, a detailed discussion of several key issues surrounding the potential for use of these cements in cemented arthroplasties, and a presentation of numerous ideas for future studies. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2008Keywords
This publication has 172 references indexed in Scilit:
- In vitro and in vivo biological responses to a novel radiopacifying agent for bone cementJournal of The Royal Society Interface, 2005
- The acoustic emission technique in orthopaedics - a reviewThe Journal of Strain Analysis for Engineering Design, 2005
- Comprehensive biocompatibility testing of a new PMMA-HA bone cement versus conventional PMMA cement in vitroJournal of Biomaterials Science, Polymer Edition, 2003
- The type of cement and failure of total hip replacementsThe Journal of Bone and Joint Surgery. British volume, 2002
- Ultrasonic characterization of the curing process of hydroxyapatite-modified bone cementJournal of Biomedical Materials Research, 2001
- Characterization of bone cements prepared with functionalized methacrylates and hydroxyapatiteJournal of Biomaterials Science, Polymer Edition, 2001
- Fatigue failure in the cement mantle of an artificial hip jointClinical Materials, 1993
- Plasma-treated ultra-high strength polyethylene fibers. Part II. Increased adhesion to poly(methyl methacrylate)Journal of Adhesion Science and Technology, 1992
- Physical characterization of acrylic bone cement cured with new accelerator systemsClinical Materials, 1991
- Rubber-modified bone cementJournal of Materials Science, 1988