Experimental aspects of high‐intensity transient signals in the detection of emboli
- 1 February 1995
- journal article
- symposium on-neurovascular-sonography
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 23 (2) , 81-87
- https://doi.org/10.1002/jcu.1870230204
Abstract
Experimental studies in the 1960s and 1970s demonstrated the high sensitivity of Doppler ultrasound in detecting gaseous bubbles. More recent studies have shown that microscopic air bubbles, as well as glass microspheres as small as 5 μ to 20 μ, cause characteristic high-intensity signals. Recently it has been demonstrated that less echogenic embolic materials such as thrombus, platelet aggregates, and atheroma can also be detected with a high sensitivity. Such “solid,” or formed-element, emboli as small as 200 μ to 400 μ can be detected; the lower size limit of detection was due to an inability to make smaller embolic particles rather than to the sensitivity of the detection process itself. Analysis of the Doppler signals provides some information about embolus size and composition, but accurate characterization in clinical practice is not possible using current technology. Studies in experimental models have allowed the detailed description of embolic signals; they appear as a short-duration, frequency-focused increase in intensity, predominantly unidirectional in the direction of flow, and usually contained within the spectral envelope. In contrast, artifacts appear as a bidirectional, high-intensity increase with maximum intensity at low frequencies. These differences have been exploited to develop automatic embolus detection programs, and an off-line version has been successfully validated in an experimental model. © 1995 John Wiley & Sons, Inc.Keywords
This publication has 19 references indexed in Scilit:
- The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models.Stroke, 1994
- Detection and volume estimation of embolic air in the middle cerebral artery using transcranial Doppler sonography.Stroke, 1994
- Computerized detection of cerebral emboli and discrimination from artifact using Doppler ultrasound.Stroke, 1993
- Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model.Stroke, 1993
- Induction of transient neurological dysfunction in baboons by platelet microemboli.Stroke, 1992
- Detection of arterial emboli using Doppler ultrasound in rabbits.Stroke, 1991
- Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography.Stroke, 1990
- The use of Doppler ultrasound in the assessment of microemboli during cardiac surgeryPerfusion, 1989
- Use of Ultrasound to Detect Fat Emboli During Total Hip ReplacementActa Orthopaedica, 1975
- In vivo Detection of Circulating Gas Emboli associated with Decompression Sickness using the Doppler FlowmeterNature, 1968