Effects of local compression on peroneal nerve function in humans
- 1 November 1993
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 11 (6) , 818-827
- https://doi.org/10.1002/jor.1100110607
Abstract
A new apparatus was developed to compress the anterior compartment selectively and reproducibly in humans. Thirty-five normal volunteers were studied to determine short-term thresholds of local tissue pressure that produce significant neuromuscular dysfunction. Local tissue fluid pressure adjacent to the deep peroneal nerve was elevated by the compression apparatus and continuously monitored for 2–3 h by the slit catheter technique. Elevation of tissue fluid pressure to within 35–40 mm Hg of diastolic blood pressure (∼40 mm Hg of in situ pressure in our subjects) elicited a consistent progression of neuromuscular deterioration including, in order, (a) gradual loss of sensation, as assessed by Semmes-Weinstein monofilaments, (b) subjective complaints, (c) reduced nerve conduction velocity, (d) decreased action potential amplitude of the extensor digitorum brevis muscle, and (e) motor weakness of muscles within the anterior compartment. Generally, higher intracompartmental pressures caused more rapid deterioration of neuromuscular function. In two subjects, when in situ compression levels were 0 and 30 mm Hg, normal neuromuscular function was maintained for 3 h. Threshold pressures for significant dysfunction were not always the same for each functional parameter studied, and the magnitudes of each functional deficit did not always correlate with compression level. This variable tolerance to elevated pressure emphasizes the need to monitor clinical signs and symptoms carefully in the diagnosis of compartment syndromes. The nature of the present studies was short term; longer term compression of myoneural tissues may result in dysfunction at lower pressure thresholds.Keywords
This publication has 19 references indexed in Scilit:
- Tissue fluid pressures: From basic research tools to clinical applicationsJournal of Orthopaedic Research, 1989
- The Compartment SyndromePublished by Wolters Kluwer Health ,1988
- Local compression patterns beneath pneumatic tourniquets applied to arms and thighs of human cadaveraJournal of Orthopaedic Research, 1987
- Effects of increased systemic blood pressure on the tissue fluid pressure threshold of peripheral nerveJournal of Orthopaedic Research, 1983
- Effects of External Compression on Blood Flow to Muscle and SkinPublished by Wolters Kluwer Health ,1982
- Compartment Syndrome after Anti-shock Trouser Use without Lower-extremity TraumaPublished by Wolters Kluwer Health ,1982
- MAS Trousers Improperly Applied Causing a Compartment Syndrome in Lower-extremity TraumaPublished by Wolters Kluwer Health ,1982
- Muscle blood flow disturbances produced by simultaneously elevated venous and total muscle tissue pressureMicrovascular Research, 1980
- Skeletal Muscle Necrosis in Pressurized Compartments Associated with Hemorrhagic HypotensionPublished by Wolters Kluwer Health ,1980
- Intramuscular Pressures with Limb CompressionNew England Journal of Medicine, 1979