Bone Remodeling and in Vivo Strain Analysis of Intact and Implanted Greyhound Proximal Femora
- 1 January 1994
- journal article
- research article
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 7 (3) , 213-233
- https://doi.org/10.3109/08941939409018287
Abstract
Pre- and poststudy motion and gait analyses of eight size-matched male greyhounds confirmed uniform loading of their femora. Subminiature strain gages implanted on the intact inferior and anterior aspects of the femoral neck in six greyhounds indicated in vivo strain variations among test animals. Motion and gait analyses confirmed uniform loading of femora following unilateral hemiarthroplasty with cobalt-chromium hip implants. In vivo strain measurements adjacent to the implants indicated large variations among test animals. A consistent direction of strain change relative to the intact femur was noted, even though strain changes varied in magnitude. Image analysis of microradiographs indicated insignificant differences in the cortical areas of implanted and intact femora. Extensive new trabecular bone formation was noted along the implant in the endosteal cavity and correlated with a combination of implant placement and exercise level. Most of the bone was formed with centrally placed implants in exercised dogs, and the least with stems on the medial neck surface in rested dogs. Iliac crest biopsies indicated that bone formation rates slowed in rested animals and remained constant throughout the study in exercised animals. All implanted femora had a thin (< 1 mm thick) aligned fibrous tissue layer separating the implant from bone. It varied in thickness as a function of the aspect of the implant. Exercised dogs had a larger proportion of fibrous tissue on the anterior and posterior aspects, while rested dogs had a larger proportion of fibrous tissue on the medial and lateral aspects.Keywords
This publication has 11 references indexed in Scilit:
- In Vivo Strain Analysis of the Greyhound Femoral DiaphysisJournal of Investigative Surgery, 1992
- Mechanical and morphological effects of strain rate on fatigue of compact boneBone, 1989
- A Polymethyl Methacrylate Method for Large Specimens of Mineralized Bone with ImplantsStain Technology, 1987
- The effect of proximally and fully porous‐coated canine hip stem design on bone modelingJournal of Orthopaedic Research, 1987
- Bone remodeling in response to in vivo fatigue microdamageJournal of Biomechanics, 1985
- Mechanically adaptive bone remodellingJournal of Biomechanics, 1982
- A hypothetical mechanism for the stimulation of osteonal remodelling by fatigue damageJournal of Biomechanics, 1982
- A study of bone remodeling using metal-polymer laminatesJournal of Biomedical Materials Research, 1981
- Stress fields in the unplated and plated canine femur calculated from in vivo strain measurementsJournal of Biomechanics, 1981
- Bone ingrowth and stress shielding with a porous surface coated fracture fixation plateJournal of Biomedical Materials Research, 1979