In Vivo Strain Analysis of the Greyhound Femoral Diaphysis
- 1 January 1992
- journal article
- case report
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 5 (2) , 91-108
- https://doi.org/10.3109/08941939209012426
Abstract
Subminiature single element and rosette strain gauges used for deformation measurement were prepared for surgical implantation using a technique published previously (Szivek JA, Magee FP. J Invest Surg. 1989;2:195–206). During surgery, gauges were placed on the anterior, lateral, and medial aspects of the mid-diaphysis of one femur in six greyhounds. Motion and gait analyses were performed to ensure uniform weight bearing prior to strain monitoring. In vivo strain measurements were obtained during normal gait at several speeds on a treadmill. After a 3-month holding period, strain gauges that were implanted on the contralateral femur were monitored. All animals were euthanized and both their femora explanted. Following embedding and histological preparation of the explanted femora, strain measurements were plotted on diagrams of the section shapes of the mid-diaphysis of each femur. Strain distribution diagrams indicated that peak strain levels and strain distributions changed during different phases of gait. Increases in gait speed increased the peak strain levels. In addition, the anterior rather than anterior-lateral aspect of the femur exhibited the highest strain during midstance. Measurements taken from rosette gauges indicated that the principal compressive strain direction was oriented slightly off axis to the long axis of the femur. Measurements from gauges placed along the length of the femur indicated an average strain change of 22.3 microstrain ± 12.2% over a 2-cm length in the mid-diaphysis. These measurements provide a baseline describing the strain state of the greyhound femur and can be used in computer modeling.Keywords
This publication has 16 references indexed in Scilit:
- The mechanical and morphological properties of bone beneath internal fixation plates of differing rigidityJournal of Orthopaedic Research, 1989
- A Long-Term in Vivo Bone Strain Measurement DeviceJournal of Investigative Surgery, 1989
- A Polymethyl Methacrylate Method for Large Specimens of Mineralized Bone with ImplantsStain Technology, 1987
- Adaptive bone-remodeling theory applied to prosthetic-design analysisJournal of Biomechanics, 1987
- Mechanical loading history and skeletal biologyJournal of Biomechanics, 1987
- The effect of proximally and fully porous‐coated canine hip stem design on bone modelingJournal of Orthopaedic Research, 1987
- Bone remodeling in response to in vivo fatigue microdamageJournal of Biomechanics, 1985
- Porous Ingrowth Fixation of the Femoral Component in a Canine Surface Replacement of the HipPublished by Wolters Kluwer Health ,1982
- A hypothetical mechanism for the stimulation of osteonal remodelling by fatigue damageJournal of Biomechanics, 1982
- Mechanical influences in bone remodeling. Experimental research on Wolff's lawJournal of Biomechanics, 1972