A Vacuum Disengager for Tritium Removal from HYLIFE-II Reactor Flibe
- 1 May 1992
- journal article
- research article
- Published by Taylor & Francis in Fusion Technology
- Vol. 21 (3P2B) , 1949-1954
- https://doi.org/10.13182/fst21-1949
Abstract
We have designed a vacuum disengager system to remove tritium from the Flibe (Li2BeF4) molten salt coolant of the HYLIFE-II fusion reactor. There is a two-stage vacuum disengager in each of three intermediate heat exchanger (IHX) loops. Each stage consists of a vacuum chamber 4 m in diameter and 7 m tall. As 0.2 mm diameter molten salt droplets fall vertically downward into the vacuum, most of the tritium diffuses out of the droplets and is pumped away. A fraction Φ ≍ 10−5 of the 8.6 MCi/day tritium source (from breeding in the Flibe and from unburned fuel) remains in the Flibe as it leaves the vacuum disengagers, and about 21 % of that permeates into the intermediate coolant loop, so about 20 Ci/day leak into the steam system. With Flibe primary coolant and a vacuum disengager, it appears that an intermediate coolant loop is not needed to prevent tritium from leaking into the steam system. An experiment is needed to demonstrate Flibe vacuum disengager operation.Keywords
This publication has 7 references indexed in Scilit:
- Tritium Permeation Losses in HYLIFE-II Heat Exchanger TubesaFusion Technology, 1991
- HYLIFE-II Inertial Confinement Fusion Reactor DesignFusion Technology, 1991
- Safety and Environmental Aspects of HYLIFE-IIFusion Technology, 1991
- Gas evolution from spheresPublished by Office of Scientific and Technical Information (OSTI) ,1991
- Tritium recovery from molten LiF-BeF2 saltFusion Engineering and Design, 1989
- The Solubilities of Hydrogen, Deuterium, and Helium in Molten Li2BeF4Industrial & Engineering Chemistry Fundamentals, 1974
- Micron and Submicron Particle ProductionIEEE Transactions on Industry Applications, 1974