Rest-inserted loading rapidly amplifies the response of bone to small increases in strain and load cycles
Open Access
- 1 May 2007
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 102 (5) , 1945-1952
- https://doi.org/10.1152/japplphysiol.00507.2006
Abstract
We hypothesized that a 10-s rest interval (at zero load) inserted between each load cycle would increase the osteogenic effects of mechanical loading near previously identified thresholds for strain magnitude and cycle numbers. We tested our hypothesis by subjecting the right tibiae of female C57BL/6J mice (16 wk, n = 70) to exogenous mechanical loading within a peri-threshold physiological range of strain magnitudes and load cycle numbers using a noninvasive murine tibia loading device. Bone responses to mechanical loading were determined via dynamic histomorphometry. More specifically, we contrasted bone formation induced by cyclic vs. rest-inserted loading (10-s rest at zero load inserted between each load cycle) by first varying peak strains (1,000, 1,250, or 1,600 με) at fixed cycle numbers (50 cycles/day, 3 days/wk for 3 wk) and then varying cycle numbers (10, 50, or 250 cycles/day) at a fixed strain magnitude (1,250 με). Within the range of strain magnitudes tested, the slope of periosteal bone formation rate (p.BFR/BS) with increasing strain magnitudes was significantly increased by rest-inserted compared with cyclical loading. Within the range of load cycles tested, the slope of p.BFR/BS with increasing load cycles of rest-inserted loading was also significantly increased by rest-inserted compared with cyclical loading. In sum, the data of this study indicate that inserting a 10-s rest interval between each load cycle amplifies bone's response to mechanical loading, even within a peri-threshold range of strain magnitudes and cycle numbers.Keywords
This publication has 37 references indexed in Scilit:
- Ground reaction forces associated with an effective elementary school based jumping interventionBritish Journal of Sports Medicine, 2004
- Rest insertion combined with high-frequency loading enhances osteogenesisJournal of Applied Physiology, 2004
- Noninvasive Loading of the Murine Tibia: An In Vivo Model for the Study of MechanotransductionJournal of Bone and Mineral Research, 2002
- Nonlinear dependence of loading intensity and cycle number in the maintenance of bone mass and morphologyJournal of Orthopaedic Research, 1998
- Mechanical loading thresholds for lamellar and woven bone formationJournal of Bone and Mineral Research, 1994
- Bone histomorphometry: Standardization of nomenclature, symbols, and units: Report of the asbmr histomorphometry nomenclature committeeJournal of Bone and Mineral Research, 1987
- Regulation of bone mass by mechanical strain magnitudeCalcified Tissue International, 1985
- Influence of hemodynamic forces on vascular endothelial function. In vitro studies of shear stress and pinocytosis in bovine aortic cells.Journal of Clinical Investigation, 1984
- A Determinant of Bone ArchitectureClinical Orthopaedics and Related Research, 1983
- Photoreceptor signals at visual thresholdNature, 1980