The ADVIA 2120 Hematology System: Flow Cytometry-Based Analysis of Blood and Body Fluids in the Routine Hematology Laboratory
- 1 March 2005
- journal article
- Published by Carden Jennings Publishing Co. in Laboratory Hematology
- Vol. 11 (1) , 47-61
- https://doi.org/10.1532/lh96.04075
Abstract
The ADVIA 2120 Hematology System was recently released by Bayer HealthCare, Diagnostics Division, as a bench-top analyzer designed for medium- to large-volume laboratories. This flow cytometry-based system uses light scatter, differential white blood cell (WBC) lysis, and myeloperoxidase and oxazine 750 staining to provide a complete blood cell count, a WBC differential, and a reticulocyte count. A cyanide-free method is used to measure hemoglobin colorimetrically. The system is automation ready; in addition to its capability for analyzing peripheral blood specimens, the analyzer is also equipped to analyze cerebrospinal fluid samples. In this article we explain the underlying technology of the ADVIA 2120, provide linearity ranges, method-specific reference ranges, and stability data, and describe novel parameters and applications that are unique to the methodology used by this instrument. Finally, we discuss research applications and future directions, such as the use of this hematology analyzer in the determination of fetal lung maturity.Keywords
This publication has 41 references indexed in Scilit:
- Effects of the Blood-Collection Tube Material and Long-term Storage on Platelet Activation Parameters on the ADVIA 120/2120 Hematology SystemLaboratory Hematology, 2005
- Normal Reference Laboratory ValuesNew England Journal of Medicine, 2004
- Automated Flow Cytometric Analysis of Blood Cells in Cerebrospinal FluidAmerican Journal of Clinical Pathology, 2004
- Assessment of platelet activation in several different anticoagulants by the Advia 120 Hematology System, fluorescence flow cytometry, and electron microscopyThrombosis and Haemostasis, 2003
- A randomized trial of iron deficiency testing strategies in hemodialysis patients11See Editorial by Besarab, p. 2412.Kidney International, 2001
- Automated Quantitation of Hemoglobin-Based Blood Substitutes in Whole Blood SamplesAmerican Journal of Clinical Pathology, 2001
- Platelet count and parameters determined by the Bayer ADVIATM 120 in reference subjects and patientsClinical and Laboratory Haematology, 2001
- Improved Platelet Counting Using Two-Dimensional Laser Light ScatterAmerican Journal of Clinical Pathology, 2000
- MyeloperoxidaseCurrent Opinion in Hematology, 2000
- Use of mean platelet component to measure platelet activation on the ADVIA 120 haematology systemCytometry, 1999