Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies
Open Access
- 3 November 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (6) , 1327-1332
- https://doi.org/10.1002/mrm.20729
Abstract
Image inhomogeneity related to high radiofrequencies is one of the major challenges for high field imaging. This inhomogeneity can be thought of as having 2 radiofrequency-field related contributors: the transmit field distribution and the reception field distribution. Adjusting magnitude and phase of currents in elements of a transmit array can significantly improve flip angle homogeneity at high field. Effective application of some well-known parallel imaging and other receive array post-processing methods removes receptivity patterns from the intensity distribution in the final image, though noise then becomes a function of position in the final image. Here simulations are used to show that, assuming high signal-to-noise ratio, very homogeneous images in the human head can be acquired with the combination of transmit arrays and some receive array reconstruction methods at frequencies as high as 600 MHz. Magn Reson Med, 2005.Keywords
This publication has 18 references indexed in Scilit:
- Focused, eight-element transceive phased array coil for parallel magnetic resonance imaging of the chest—Theoretical considerationsMagnetic Resonance in Medicine, 2005
- Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scalingMagnetic Resonance in Medicine, 2004
- Efficient high‐frequency body coil for high‐field MRIMagnetic Resonance in Medicine, 2004
- A Numerical Analysis of Radio-Frequency Power Requirements in Magnetic Resonance Imaging ExperimentIEEE Transactions on Microwave Theory and Techniques, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coilMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- The NMR phased arrayMagnetic Resonance in Medicine, 1990
- Segmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray MatterJournal of Computer Assisted Tomography, 1989
- Amplitude- and frequency-modulated pulses to achieve 90° plane rotations with inhomogeneous B1 fieldsJournal of Magnetic Resonance (1969), 1987