Deep brain stimulation for Parkinson's disease: Surgical issues
- 1 June 2006
- journal article
- review article
- Published by Wiley in Movement Disorders
- Vol. 21 (S14) , S197-S218
- https://doi.org/10.1002/mds.20956
Abstract
Numerous factors need to be taken into account when implanting deep brain stimulation (DBS) systems into patients with Parkinson's disease. The surgical procedure itself can be divided into immediate preoperative, intraoperative, and immediate postoperative phases. Preoperative considerations include medication withdrawal issues, stereotactic equipment choices, imaging modalities, and targeting strategy. Intraoperative considerations focus on methods for physiological confirmation of a given target for DBS electrode deployment. Terms such as microelectrode recording, microstimulation, and macrostimulation will be defined to clarify inconsistencies in the literature. Advantages and disadvantages of each technique will be addressed. Furthermore, operative decisions such as staging, choice of electrode and implantable pulse generator, and methods of device fixation will be outlined. Postoperative issues include imaging considerations, including magnetic resonance safety, device–device interactions, and immediate surgical complications pertaining to the DBS procedure. This report outlines answers to a series of questions developed to address all aspects of the DBS surgical procedure and decision‐making with a systematic overview of the literature (until mid‐2004) and by the expert opinion of the authors. This is a report from the Consensus on Deep Brain Stimulation for Parkinson's Disease, a project commissioned by the Congress of Neurological Surgeons and the Movement Disorder Society. It outlines answers to a series of questions developed to address all surgical aspects of deep brain stimulation. © 2006 Movement Disorder SocietyKeywords
This publication has 88 references indexed in Scilit:
- Lack of agreement between direct magnetic resonance imaging and statistical determination of a subthalamic target: the role of electrophysiological guidanceJournal of Neurosurgery, 2002
- Implantation of deep brain stimulators into subthalmic nucleus: technical approach and magnetic imaging—verified electrode locationsJournal of Neurosurgery, 2002
- Relevance of Image Fusion for Target Point Determination in Functional NeurosurgeryActa Neurochirurgica, 2002
- Targeting the Subthalamic NucleusStereotactic and Functional Neurosurgery, 2001
- Subthalamic Stimulation for Parkinson's DiseaseArchives of Medical Research, 2000
- Bilateral subthalamic stimulation for Parkinson's disease by using three-dimensional stereotactic magnetic resonance imaging and electrophysiological guidanceJournal of Neurosurgery, 2000
- A prospective comparison between three-dimensional magnetic resonance imaging and ventriculography for target-coordinate determination in frame-based functional stereotactic neurosurgeryJournal of Neurosurgery, 1999
- Targeting for Thalamic Deep Brain Stimulator Implantation without Computer Guidance: Assessment of Targeting AccuracyStereotactic and Functional Neurosurgery, 1999
- A Phantom Study to Assess the Accuracy of Stereotactic Localization, Using T1-weighted Magnetic Resonance Imaging with the Leksell Stereotactic SystemNeurosurgery, 1996
- The Application Accuracy of Stereotactic FramesNeurosurgery, 1994