Adjunctive Antibiotic/Anticoagulant Lock Therapy in the Treatment of Bacteremia Associated with the Use of a Subcutaneously Implanted Hemodialysis Access Device
- 1 November 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 46 (6) , 767-770
- https://doi.org/10.1097/00002480-200011000-00021
Abstract
To improve vascular access for hemodialysis, a new device (Dialock Hemodialysis Access System, Biolink Corporation, Middleboro, MA) has been developed. Implanted subcutaneously, the device is accessed by percutaneous puncture. Attached to the device are two catheters that are implanted into the superior vena cava or right atrium. Clinical results thus far have been promising. However, use of this device is not free from infectious complications. In the present pilot study, 25 maintenance hemodialysis patients were implanted with 26 Dialock devices. The incidence of bacteremia was 2.9/1,000 catheter days. In 14 episodes of bacteremia in 8 patients the infection was successfully treated with a combination of systemic antibiotic treatment and adjunctive antibiotic/anticoagulant lock therapy. The lock therapy entailed the instillation of both an antibiotic and an anticoagulant into the device. We believe that the antibiotic/anticoagulant lock technique is an effective, adjunctive therapeutic modality in the treatment of infections related to the use of indwelling vascular access devices.Keywords
This publication has 21 references indexed in Scilit:
- Haemodialysis catheter-related infection: time for actionNephrology Dialysis Transplantation, 1999
- The hemodialysis catheter conundrum: Hate living with them, but can’t live without themKidney International, 1999
- Dialock: a new vascular access device for extracorporeal renal replacement therapy. Preliminary clinical results.Nephrology Dialysis Transplantation, 1999
- ANTIBIOTIC LOCK IN THE TREATMENT OF INFECTIONS ASSOCIATED WITH THE USE OF A SUBCUTANEOUSLY IMPLANTED HEMODIALYSIS ACCESS DEVICEAsaio Journal, 1999
- Development of a New Approach to Vascular AccessArtificial Organs, 1999
- Initial results of a new access device for hemodialysis: Technical NoteKidney International, 1998
- New Access Device for HemodialysisAsaio Journal, 1998
- Elimination of Intraluminal Colonization by Antibiotic Lock in Silicone Vascular CathetersNutrition, 1998
- Permanent Vascular Access: A Nephrologist's ViewAmerican Journal of Kidney Diseases, 1993
- Prospective Evaluation of a Dacron Cuffed Hemodialysis Catheter for Prolonged UseAmerican Journal of Kidney Diseases, 1988