Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children
- 1 May 1984
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 19 (5) , 634-638
- https://doi.org/10.1128/jcm.19.5.634-638.1984
Abstract
The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and the direct plating of the entire blood lysate on agar media appropriate for the growth of fastidious microorganisms. Of 1,500 paired samples inoculated into the two systems, 68 were positive for 73 clinically significant organisms. The Isolator 1.5 recovered 81% of the positive cultures compared with 84% recovered by the BACTEC system. When paired blood samples with disproportionate volumes were excluded, the Isolator 1.5 detected 3% more positive cultures. More isolates of Streptococcus pneumoniae and Neisseria meningitidis were recovered by the Isolator 1.5, whereas Haemophilus influenzae was recovered most often in the BACTEC bottles (P greater than 0.1). The contamination rates were 8.7 and 3.1% for the Isolator 1.5 and the BACTEC system, respectively. In cultures positive by both systems, the mean time to detection was 4.1 h faster with the Isolator 1.5. The mean time to obtain isolated colonies was 26.6 h faster with the Isolator 1.5. These data indicate the potential value of the Isolator 1.5 microbial tube as a simple, rapid, and sensitive method for the detection of bacteremia in children.This publication has 13 references indexed in Scilit:
- Inactivation of the polyanionic detergent sodium polyanetholsulfonate by hemoglobinJournal of Clinical Microbiology, 1983
- Clinical laboratory comparison of lysis-centrifugation and BACTEC radiometric blood culture techniquesJournal of Clinical Microbiology, 1983
- Evaluation of a lysis-centrifugation and biphasic bottle blood culture system during routine useJournal of Clinical Microbiology, 1983
- Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from bloodJournal of Clinical Microbiology, 1983
- False no-growth blood cultures in pneumococcal pneumoniaJournal of Clinical Microbiology, 1980
- Improved blood culture technique based on centrifugation: clinical evaluationJournal of Clinical Microbiology, 1979
- New centrifugation blood culture deviceJournal of Clinical Microbiology, 1978
- Detection and quantitation of bacteremia in childhoodThe Journal of Pediatrics, 1977
- Blood culture technique based on centrifugation: clinical evaluationJournal of Clinical Microbiology, 1976
- Effect of sodium polyanethol sulfonate in blood culturesJournal of Clinical Microbiology, 1975